    International comparisons of intraocular pressures, as measured by Tono-Pen and Goldmann applanation tonometry, in healthy adults: A meta-analysis.

    • William J Keller.
    • Medical Education, Nova Southeastern University, Kiran C. Patel College of Allopathic Medicine (NSU-MD), Fort Lauderdale, Florida, USA.
    • Medicine (Baltimore). 2023 Mar 10; 102 (10): e33078e33078.

    BackgroundInvestigate intraocular pressure (IOP), as measured by Tono-Pen (TP) and Goldmann applanation tonometry (GAT), in healthy adults. Provide an updated synthesis of multinational, primary studies, reported during the 10-year period 2011 to 2021 and offer an evidence-based benchmark, against which IOP can be evaluated across subject variables and pathologies. Three primary research questions are investigated: Is there a statistically significant difference between IOP measured by TP and GAT? If yes, is the difference clinically significant? Is measurement of IOP affected by the country or setting location, in which the measurements are made?MethodsAn aggregate meta-analysis was conducted on 22 primary studies, from 15 different countries. IOP measurements were made from each healthy adult subject, with both the TP and GAT. Primary studies were identified and data extracted according to recommended preferred reporting items for systematic reviews and meta-analysis protocol guidelines. Meta-analysis summary results are reported as the point estimate of the raw mean difference of IOP.ResultsMeta-analysis reveals a statistically significant difference in raw mean differences in IOP, when measured by TP and GAT, in the healthy adult population. Tono-Pen IOP measurements are higher than GAT IOP measurements. The point estimate for the summary effect size = -0.73 mm Hg, P = .03. The prediction interval for the true effect size, in 95% of all comparable populations, is -4.03 to 2.58 mm Hg. There is no clinically significance difference in IOP when measured by TP and GAT. Meta-regression analysis reveals statistically significant differences in measurement of IOP by countries, R2 analog = 0.75, P = .001. There is no statistically significant difference in measurement of IOP as a function of measurement location setting, R2 analog = -0.17, P = .65.ConclusionsIOP measured by TP are marginally higher compared to GAT, in the healthy adult population. However, from a clinical practice perspective, TP and GAT produce similar IOP measurements. There is evidence of significant variabilities in IOP measurements as a function of country. IOP measurements collected in a research laboratory setting are similar to IOP collected in a clinical setting. Results have implications for the primary care physician requiring a portable, inexpensive, reliable, and easily administered instrument to assess IOP.Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…