J. Cardiothorac. Vasc. Anesth. · Jun 2023
The Use of Contrast May Improve Aortic Valve Assessment During Transesophageal Echocardiography.
- Zachary A Haas, Cheng Qian, Matthew A Dabski, Samira Jafarisis, Jonathan Cousins, Stanley F Fernandez, and Nader D Nader.
- Cardiothoracic Anesthesiology, University at Buffalo, Jacobs School of Medicine and Biomedical Sciences, Buffalo, NY.
- J. Cardiothorac. Vasc. Anesth. 2023 Jun 1; 37 (6): 904910904-910.
ObjectivesThe Doppler profile that quantifies the degree of aortic stenosis is essential, as an inaccurate measurement can alter the surgical plan. The authors aimed to examine the level of agreement between the contrast and noncontrast methods of aortic valve sizing during intraoperative transesophageal echocardiography (TEE).SettingAt a tertiary hospital.ParticipantsA total of 30 patients undergoing surgical aortic valve replacement for a stenotic valve.InterventionsPerflutren lipid microsphere contrast injection.Measurements And Main ResultsThe authors reviewed Doppler studies of 30 consecutive patients undergoing aortic valve replacement in whom a contrast agent was given (perflutren lipid microsphere). They measured the peak and/or mean aortic valve gradients and velocity time integral readings through the left ventricular outflow tract (LVOT), and the aortic valve before and after administering the contrast agent. The aortic valve area was then calculated using both methods. Paired t tests and Bland-Altman analyses were used to examine the bias and the level of agreement between the 2 processes. By not using a contrast agent, the aortic valve area was overestimated by 0.26 cm2 compared to those measured by transthoracic echocardiography (TTE) (p < 0.001). Using a contrast agent, TEE measurements were comparable to those obtained by TTE. Moreover, the peak and mean aortic valve gradients were underestimated by 19 and 11 mmHg, respectively (p value <0.001). Adding contrast did not affect the pulse-wave Doppler readings of the V1 velocity of the LVOT.ConclusionThis discrepancy is significant and could affect the decision to replace the aortic valve. When evaluating the aortic valve with TEE, the authors recommend using a contrast agent to improve the Doppler profile and to obtain a more accurate measurement of the aortic valve area.Published by Elsevier Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.