-
- Andrew D Posner, Afshin A Anoushiravani, Eric M Perloff, Khushdeep S Vig, Michael P Smith, and Michael T Mulligan.
- Department of Orthopaedic Surgery, Albany Medical Center, Albany, NY, USA.
- Injury. 2023 Mar 12.
IntroductionGluteal compartment syndrome is an uncommon entity and physicians may use intracompartmental pressure measurements for confirmation of the clinical diagnosis, or in cases where the physical exam is indeterminate. However, there is a paucity of literature describing a safe and reproducible technique to measure gluteal intracompartmental pressures during the diagnosis of gluteal compartment syndrome. The purpose of this cadaveric study is to evaluate the sole previous technique described in the literature to measure gluteal intracompartmental pressures and provide a modified technique which can be safely and reliably utilized clinically.MethodsA cadaveric study with three phases was performed in 16 gluteal regions in 8 cadavers. In the first phase, the previously described technique was assessed. In the second phase, a modified set of techniques was created and evaluated. In the third phase, inter-user reliability of the modified set of techniques was assessed and calculated using Cohen's ĸ coefficient. In all three phases, methylene blue was injected through pressure monitoring needles into the gluteus maximus (GMax), gluteus medius/minimus (GMM), and the tensor fascia lata (TFL) compartments. Following dissection, rate of successful penetration into each targeted compartment and distance from the neurovascular structures was recorded.ResultsThe previously described set of techniques was found to be variable. The modified set of techniques was effective, successfully reaching the GMax, GMM, and TFL compartments in 100%, 100%, and 81% of attempts, respectively. Inter-user reliability was excellent (ĸ = 1) for the techniques to reach both the GMax and GMM compartments, and moderate (ĸ = 0.54) for the technique to reach the TFL compartment. Within the GMax, the pressure monitoring needle was at a mean of 5.4±0.6 cm, 4.1±0.7 cm, 6.4±0.5 cm from the sciatic nerve (SN), superior gluteal nerve (SGN), and inferior gluteal nerve (IGN), respectively. Within the GMM, the pressure monitoring needle was at a mean of 9.7±1.4 cm, 7.4±1.3 cm, 11.1±1.7 cm from the SN, SGN, and IGN, respectively.ConclusionThe modified set of techniques presented allows the three gluteal compartments to be safely and reproducibly reached to measure intracompartmental pressures during the diagnosis of gluteal compartment syndrome.Copyright © 2023. Published by Elsevier Ltd.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.