-
- Emir Benca, Beatrice Ferrante, Ewald Unger, Andreas Strassl, Lena Hirtler, Rickard Brånemark, Reinhard Windhager, and Gerhard M Hobusch.
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, 1090 Vienna, Austria.
- Medicina (Kaunas). 2023 Feb 22; 59 (3).
AbstractBackground and Objectives: The treatment of transfemoral amputees using osseointegrated implants for prosthetic anchorage requires accurate implant positioning when using threaded bone-anchoring implants due to the curvature of the femur and the risk of cortical penetration in misaligned implants. This study investigated the accuracy and precision in implant positioning using additively manufactured case-specific positioning guides. Materials and Methods: The geometry and density distribution of twenty anatomic specimens of human femora were assessed in quantitative computed tomography (QCT) scanning. The imaging series were used to create digital 3D specimen models, preoperatively plan the optimal implant position and manufacture specimen-specific positioning guides. Following the surgical bone preparation and insertion of the fixture (threaded bone-anchoring element) (OPRA; Integrum AB, Mölndal, Sweden), a second QCT imaging series and 3D model design were conducted to assess the operatively achieved implant position. The 3D models were registered and the deviations of the intraoperatively achieved implant position from the preoperatively planned implant position were analyzed as follows. The achieved, compared to the planned implant position, was presented as resulting mean hip abduction or adduction (A/A) and extension or flexion (E/F) and mean implant axis offset in medial or lateral (M/L) and anterior or posterior (A/P) direction measured at the most distal implant axis point. Results: The achieved implant position deviated from the preoperative plan by 0.33 ± 0.33° (A/A) and 0.68 ± 0.66° (E/F) and 0.62 ± 0.55 mm (M/L) and 0.68 ± 0.56 mm (A/P), respectively. Conclusions: Using case-specific guides, it was feasible to achieve not only accurate but also precise positioning of the implants compared to the preoperative plan. Thus, their design and application in the clinical routine should be considered, especially in absence of viable alternatives.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.