-
- Mohammed Khashab, Moyassar Karami, Muath Alswat, and Mohamed Elkhalifa.
- Department Surgery, Orthopaedic Division, Ministry of National Guard-Health Affairs, Jeddah 22384, Saudi Arabia.
- Medicina (Kaunas). 2023 Mar 16; 59 (3).
AbstractBackground and Objective: Minimally Invasive Transforaminal Lumbar Interbody Fusion (MIS-TLIF) has been investigated and shown excellent short- and long-term outcomes. In this paper, we describe a new MIS-TLIF technique and pedicle screw insertion using a marker screw as a guidance method. Moreover, we report perioperative, postoperative, and patient-related outcomes. In addition, this paper outlines major differences in radiation exposure, cost effectiveness and accuracy of Marker Screw Minimally Invasive Transforaminal Interbody Fusion (MS-MIS TLIF) compared to other techniques. We report our technique to share our knowledge and experience with the aim of achieving a better MIS-TLIF that would help both surgeons and patients. Materials and Methods: A prospective case series was conducted between October 2018 and February 2021. Patients undergoing MS-MIS TLIF with marker screws were consecutively included. The surgery did not exceed two levels. The patients' medical records were reviewed, and the included patients were asked to complete two outcome-questionnaires before surgery and at the six-month visit. The surgical technique is described in this paper. Results: A total of 37 patients were recruited. The mean age was 57.35 ± 12.8 years, and more than half of the patients were females. The most common indications for surgery were degenerative disc disease and spondylolisthesis, with the typical level at L4-5. The operative time was 3.02 ± 0.83 h, while the estimated blood loss was 127.7 ± 71.1 mL. The average time for ambulation and hospitalization was 1 ± 1.1 and 2.84 ± 1.4 days, respectively. The patients described significant improvement in both questionnaires. No screw-related complications or screw revisions were needed up to two years of follow-up. Conclusions: The use of marker screws for pedicle screw placement through a minimally invasive fashion is shown to be a promising technique that can overcome many drawbacks, including cost, operative time, and radiation exposure. Performing MS-MIS TLIF can achieve a 360- degree fusion compared to percutaneous MIS-TLIF.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.