-
J Clin Monit Comput · Apr 2023
Observational StudyCarotid flow as a surrogate of the left ventricular stroke volume.
- Issac Cheong, Victoria Otero Castro, Fernando Ariel Sosa, Bárbara Tort Oribe, Pablo Martín Merlo, and Francisco Marcelo Tamagnone.
- Department of Critical Care Medicine, Sanatorio de los Arcos, Buenos Aires, Argentina. issac_cheong@hotmail.com.
- J Clin Monit Comput. 2023 Apr 1; 37 (2): 661667661-667.
AbstractTransthoracic echocardiography (TTE) is a fundamental tool for hemodynamic monitoring in critical patients. It allows evaluating the left ventricle's stroke volume based on the measurement of the velocity-time integral (VTI) of the left ventricle outflow tract (LVOT). However, in the intensive care unit obtaining adequate echocardiographic views may present a challenge. We propose to measure, as a surrogate of the stroke volume, the carotid flow with a novel technique. This is an observational, prospective, and simple blind study, conducted in the intensive care unit of Sanatorio de los Arcos and Hospital Aleman, in Buenos Aires, Argentina. We measured the carotid systodiastolic flow (CSD) VTI and the carotid systolic flow (CS) VTI at the level of the left supraclavicular fossa and we compared it with the LVOT VTI obtained by TTE. We evaluated 43 subjects. Spearman's correlation coefficient between LVOT VTI and CS VTI was 0.81 (95% CI 0.67-0.89) and between LVOT VTI and CSD VTI was 0.89 (95% CI 0.81-0.94). The Bland-Altman method analysis of the 5-chamber apical window LVOT VTI compared to the CSD VTI showed a bias of - 0.2 (95% CI - 0.82 to 0.43), with a concordance interval between - 4.2 (95% CI - 5.2 to - 3.1) and 3.8 cm (95% CI 2.7 to 4.9). The percentage error was 37.9%. Almost 100% of the values fell within the concordance limits, and no trend was observed in bias across the spectrum of mean variables. Although the CSD VTI could not be interchangeable with the LVOT VTI, it could be considered as its surrogate.© 2022. The Author(s), under exclusive licence to Springer Nature B.V.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.