-
Observational Study
Cardiovascular and Pulmonary Responses to Acute Use of Electronic Nicotine Delivery Systems and Combustible Cigarettes in Chronic Users.
- Matthew C Tattersall, Christina M Hughey, Thomas M Piasecki, Claudia E Korcarz, Kristin M Hansen, Nancy R Ott, Nathan Sandbo, Michael C Fiore, Timothy B Baker, and James H Stein.
- Department of Medicine, Division of Cardiovascular Medicine, University of Wisconsin School of Medicine and Public Health, Madison, WI.
- Chest. 2023 Sep 1; 164 (3): 757769757-769.
BackgroundThe acute cardiovascular and pulmonary effects of contemporary electronic nicotine delivery systems (ENDS) in long-term users are not known.Research QuestionWhat are the cardiovascular and pulmonary responses to an acute 15-min product use challenge with ENDS and combustible cigarettes in regular nicotine-containing product users compared with control participants who do not use tobacco or vape?Study Design And MethodsObservational challenge study before and after nicotine-containing product use of 395 individuals who used ENDS exclusively (n = 164; exhaled carbon monoxide level, < 5 parts per million [ppm]; positive urine NicCheck I [Mossman Associates] results, 82%; fourth-generation ENDS), participants who smoked cigarettes exclusively (n = 117; carbon monoxide level, > 5 ppm; positive urine NicCheck I results), and control participants (n = 114; carbon monoxide level, < 5 ppm; negative urine NicCheck I results).ResultsDuring the 15-min product challenge, cigarette users took a median of 14.0 puffs (interquartile range [IQR], 9.3 puffs); ENDS users took 9.0 puffs (IQR, 7.5 puffs; P < .001). After product challenge, compared with control participants, ENDS users showed greater increases in adjusted mean differences in systolic BP (5.6 mm Hg [95% CI, 4.4-6.8 mm Hg] vs 2.3 mm Hg [95% CI, 0.8-3.8 mm Hg]; P = .001), diastolic BP (4.2 mm Hg [95% CI, 3.3-5.0 mm Hg] vs 2.0 mm Hg [95% CI, 1.1-3.0 mm Hg; P = .003), and heart rate (4.8 beats/min [95% CI, 4.0-5.6 beats/min] vs -1.3 beats/min [95% CI, -2.2 to -0.3 beats/min]; P < .001) and greater reductions in brachial artery diameter (-0.011 cm [95% CI, -0.013 to 0.009 cm] vs -0.006 cm [95% CI, -0.004 to -0.009 cm]; P = .003), time-domain heart rate variability (-7.2 ms [95% CI, -10.5 to -3.7 ms] vs 3.6 ms [95% CI, 1.6-9.3 ms]; P = .001), and FEV1 (ENDS: -4.1 [95% CI, -5.4 to -2.8] vs control participants: -1.1 [95% CI, -2.7 to 0.6]; P = .005) with values similar to those of cigarette users. ENDS users performed worse than control participants on all exercise parameters, notably metabolic equivalents (METs; adjusted mean difference, 1.28 METs [95% CI, 0.73-1.83 METs]; P < .001) and 60-s heart rate recovery (adjusted mean difference, 2.9 beats/min [95% CI, 0.7-5.0 beats/min]; P = .008).InterpretationENDS users had acute worsening of blood pressure, heart rate, and heart rate variability, as well as vasoconstriction, impaired exercise tolerance, and increased airflow obstruction after vaping, compared to control participants.Trial RegistryClinicalTrials.gov; No.: NCT03863509; URL: www.Clinicaltrialsgov.Copyright © 2023 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.