-
- Douglas Slobod, Elena Spinelli, Stefania Crotti, Alfredo Lissoni, Alessandro Galazzi, Giacomo Grasselli, and Tommaso Mauri.
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda, Ospedale Maggiore Policlinico, Via F. Sforza 35, 20122, Milan, Italy.
- Crit Care. 2023 Apr 18; 27 (1): 145145.
BackgroundOptimal noninvasive respiratory support for patients with hypoxemic respiratory failure should minimize work of breathing without increasing the transpulmonary pressure. Recently, an asymmetrical high flow nasal cannula (HFNC) interface (Duet, Fisher & Paykel Healthcare Ltd), in which the caliber of each nasal prong is different, was approved for clinical use. This system might reduce work of breathing by lowering minute ventilation and improving respiratory mechanics.MethodsWe enrolled 10 patients ≥ 18 years of age who were admitted to the Ospedale Maggiore Policlinico ICU in Milan, Italy, and had a PaO2/FiO2 < 300 mmHg during HFNC support with a conventional cannula. We investigated whether the asymmetrical interface, compared to a conventional high flow nasal cannula, reduces minute ventilation and work of breathing. Each patient underwent support with the asymmetrical interface and the conventional interface, applied in a randomized sequence. Each interface was provided at a flow rate of 40 l/min followed by 60 l/min. Patients were continuously monitored with esophageal manometry and electrical impedance tomography.ResultsApplication of the asymmetrical interface resulted in a -13.5 [-19.4 to (-4.5)] % change in minute ventilation at a flow rate of 40 l/min, p = 0.006 and a -19.6 [-28.0 to (-7.5)] % change at 60 l/min, p = 0.002, that occurred despite no change in PaCO2 (35 [33-42] versus 35 [33-43] mmHg at 40 l/min and 35 [32-41] versus 36 [32-43] mmHg at 60 l/min). Correspondingly, the asymmetrical interface lowered the inspiratory esophageal pressure-time product from 163 [118-210] to 140 [84-159] (cmH2O*s)/min at a flow rate of 40 l/min, p = 0.02 and from 142 [123-178] to 117 [90-137] (cmH2O*s)/min at a flow rate of 60 l/min, p = 0.04. The asymmetrical cannula did not have any impact on oxygenation, the dorsal fraction of ventilation, dynamic lung compliance, or end-expiratory lung impedance, suggesting no major effect on PEEP, lung mechanics, or alveolar recruitment.ConclusionsAn asymmetrical HFNC interface reduces minute ventilation and work of breathing in patients with mild-to-moderate hypoxemic respiratory failure supported with a conventional interface. This appears to be primarily driven by increased ventilatory efficiency due to enhanced CO2 clearance from the upper airway.© 2023. The Author(s).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.