• J. Thorac. Cardiovasc. Surg. · Oct 2023

    Use of the Inspiris Valve in the Native Right Ventricular Outflow Tract is Associated with Early Prosthetic Regurgitation.

    • Stephanie N Nguyen, Alice V Vinogradsky, Riley Sevensky, Matthew A Crystal, Emile A Bacha, and Andrew B Goldstone.
    • Section of Pediatric and Congenital Cardiac Surgery, New York Presbyterian-Morgan Stanley Children's Hospital, Columbia University Irving Medical Center, New York, NY.
    • J. Thorac. Cardiovasc. Surg. 2023 Oct 1; 166 (4): 12101221.e81210-1221.e8.

    ObjectiveThe Inspiris Resilia prosthesis (Edwards Lifesciences) has been increasingly used in the pulmonic position with limited performance data. We sought to investigate its durability as a surgical pulmonary valve replacement (PVR).MethodsWe retrospectively reviewed patients who underwent PVR or conduit replacement with an Inspiris or non-Inspiris valve/conduit from 2018 to 2022. The primary end point was freedom from a composite of at least moderate pulmonary regurgitation, pulmonary stenosis, or valve/conduit reintervention. Secondary end points were individual components of the composite outcome. To account for baseline differences, propensity matching identified 70 patient pairs.ResultsA total of 227 patients (median age: 19.3 years [interquartile range, 11.8-34.4]) underwent PVR or conduit replacement (Inspiris: n = 120 [52.9%], non-Inspiris: n = 107 [47.1%]). Median follow-up was 26.6 months [interquartile range, 12.4-41.1]. Among matched patients, 2-year freedom from valve failure was lower in the Inspiris group (53.5 ± 9.3% vs 78.5 ± 5.9%, P = .03), as was freedom from at least moderate pulmonary regurgitation (54.2 ± 9.6% vs 86.4 ± 4.9%, P < .01). There was no difference in 2-year freedom from at least moderate pulmonary stenosis (P = .61) or reintervention (P = .92). Inspiris durability was poorer when implanted in the native right ventricular outflow tract compared with as a conduit, with 18-month freedom from valve failure of 59.0 ± 9.5% versus 85.9 ± 9.5% (P = .03).ConclusionsEarly durability of the Inspiris valve is poor when implanted in the native right ventricular outflow tract; its unique design may be incompatible with the compliant pulmonary root. Modified implantation techniques or alternative prostheses should be considered.Copyright © 2023 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…