• Medicina · Apr 2023

    Accuracy of Computer-Guided Implantology with Pilot Drill Surgical Guide: Retrospective 3D Radiologic Investigation in Partially Edentulous Patients.

    • Federico Gelpi, Nicolò Modena, Alessandro Poscolere, Fabio Bernardello, Lorena Torroni, and Daniele De Santis.
    • Head and Neck Department, Department of Surgery, Dentistry, Pediatrics and Gynecology, University of Verona, 37124 Verona, Italy.
    • Medicina (Kaunas). 2023 Apr 10; 59 (4).

    AbstractBackground and Objectives: Implant placement with static navigation enables the reaching of a correct position of implants from an anatomical and prosthetic point of view. Different approaches of static navigation are described in the scientific literature, and the pilot-guided approach is one of the least investigated. The aim of the present study is the evaluation of the accuracy of implant insertion using a pilot drill template. Materials and Methods: Fifteen partially edentulous patients, requiring an implant rehabilitation of at least one implant, were enrolled. Pre- and post-operative low-dose CTs were acquired to measure the differences between final positions of implants and virtually planned ones. Three linear discrepancies (coronal, apical, and depth), two angular ones (bucco-lingual and mesio-distal), and the imprecision area were evaluated. Correlations between accuracy and rehabilitated jaws, sectors, and implant length and diameters were also analyzed. Results: Forty implants were inserted in fifteen patients using pilot drill templates. Mean coronal deviation was 1.08 mm, mean apical deviation was 1.77 mm, mean depth deviation was -0.48 mm, mean bucco-lingual angular deviation was 4.75°, and mean mesio-distal one was 5.22°. The accuracy was statistically influenced only by the rehabilitated jaw for coronal discrepancy and sectors and implant diameter for bucco-lingual angular deviations. Conclusions: The pilot drill template could represent a predictable solution to obtain a correct implant placement. Nonetheless, a safety margin of at least 2 mm should be respected during implant planning to prevent damages to anatomical structures. Therefore, the tool is helpful in order to prosthetically drive the implants; still, great attention must be paid in fully relying on this procedure when approaching dangerous structures such as nerves and vessels.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…