• Pediatr Crit Care Me · Oct 2023

    Observational Study

    Agreement Between Measured Weight and Fluid Balance in Mechanically Ventilated Children in Intensive Care.

    • Ben Gelbart, Vanessa Marchesini, Sudeep Kumar Kapalavai, Andrea Veysey, Alyssa Serratore, Jessica Appleyard, Rinaldo Bellomo, Warwick Butt, and Trevor Duke.
    • Paediatric Intensive Care Unit, University of Melbourne, Murdoch Children's Research Institute, Royal Children's Hospital, Parkville, VIC, Australia.
    • Pediatr Crit Care Me. 2023 Oct 1; 24 (10): e459e467e459-e467.

    ObjectivesTo investigate the agreement between change in body weight (BW) and fluid balance (FB), and the precision and safety of BW measurement in mechanically ventilated infants in intensive care.DesignProspective observational study.SettingTertiary PICU.PatientsInfants following cardiac surgery, at baseline, 24 hours, and 48 hours.InterventionsBW and FB measurement at three time points.Measurements And Main ResultsBetween May 2021 and September 2022, we studied 61 children. The median age was 8 days (interquartile range [IQR], 1.0-14.0 d). The median BW at baseline was 3,518 g (IQR, 3,134-3,928 g). Change in BW was -36 g (IQR, -145 to 105 g) and -97 g (IQR, -240 to -28 g) between baseline and 24 hours, and between 24 and 48 hours, respectively. Change in FB was -82 mL (IQR, -173 to 12 mL) and -107 mL (IQR, -226 to 103) between baseline and 24 hours, and between 24 and 48 hours, respectively. In Bland-Altman analyses, the mean bias between BW and FB at 24 and 48 hours was 54 g (95% CI, 12-97) and -43 g (95% CI, -108 to 23), respectively. This exceeded 1% of the median BW, and limits of agreement ranged from 7.6% to 15% of baseline BW. The precision of paired weight measurements, performed sequentially at each time interval, was high (median difference of ≤1% of BW at each time point). The median weight of connected devices ranged from 2.7% to 3% of BW. There were no episodes of tube or device dislodgments and no change in vasoactive therapies during weight measurements.ConclusionsThere is moderate agreement between the changes in FB and BW, albeit greater than 1% of baseline BW, and the limits of this agreement are wide. Weighing mechanically ventilated infants in intensive care is a relatively safe and precise method for estimating change in fluid status. Device weight represents a relatively large proportion of BW.Copyright © 2023 by the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…