    Efficacy of an automated secretion removal technology at different inspiratory pressures.

    • Anne H Nielsen, Dan S Karbing, Christoffer G Sølling, Robert R Winding, Stephen E Rees, and Nilanjan Dey.
    • Department of Anaesthesiology and Intensive Care, Gødstrup Hospital, Herning, Denmark.
    • Respir Care. 2023 Nov 1; 68 (11): 150215091502-1509.

    BackgroundEndotracheal suctioning is resource demanding, causes patient discomfort, and is associated with adverse effects. A new artificial cough method has been developed for automated secretion removal by using rapid deflation and inflation of the endotracheal tube cuff during the inspiratory phase of mechanical ventilation. This method has been evaluated in a bench model and in animals but not in human subjects. The aim of this study was to investigate whether this method can remove the need for endotracheal suctioning in subjects and whether this is dependent on ventilator settings.MethodsThis prospective, non-controlled study recruited 20 subjects on invasive mechanical ventilation. On the clinical need for endotracheal suctioning, the automatic cough procedure was applied 3 times over 30 s, with this repeated at higher ventilatory pressure and lower respiratory frequency if considered unsuccessful. Success was determined by removal of the clinical need for suctioning. Subject safety and comfort was measured by using the Critical-Care Pain Observation Tool before and after the procedure, and negative effects were recorded. To assess intra-subject variability, the procedure was performed on 3 different occasions for each subject.ResultsThe procedure was successful in 18 of 20 subjects (90%), with mean subject success rates of 53% at low settings (peak inspiratory pressure 21.8 ± 3.8 cm H2O) and 83% at high settings (peak inspiratory pressure 25.6 ± 3.6 cm H2O). The Critical-Care Pain Observation Tool category remained unchanged in 30 procedures (77%), improved in 7 (18%), and deteriorated in 2 (5%).ConclusionsThis study illustrated the potential for significant reduction in the clinical need for endotracheal suctioning after the use of an automated artificial cough procedure at both low and high peak inspiratory pressures, and that was well tolerated.Copyright © 2023 by Daedalus Enterprises.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…