-
J Clin Monit Comput · Aug 2023
Multisensory alarm to benefit alarm identification and decrease workload: a feasibility study.
- Derek Rios, Nuphar Katzman, Kendall J Burdick, May Gellert, Jessica Klein, Yuval Bitan, and Joseph J Schlesinger.
- Department of Neuroscience Nashville, Vanderbilt University, Nashville, TN, 37235, USA.
- J Clin Monit Comput. 2023 Aug 1; 37 (4): 105110591051-1059.
AbstractThe poor design of conventional auditory medical alarms has contributed to alarm desensitization, and eventually, alarm fatigue in medical personnel. This study tested a novel multisensory alarm system which aims to help medical personnel better interpret and respond to alarm annunciation during periods of high cognitive load such as those found within intensive care units. We tested a multisensory alarm that combined auditory and vibrotactile cues to convey alarm type, alarm priority, and patient identity. Testing was done in three phases: control (conventional auditory), Half (limited multisensory alarm), and Full (complete multisensory alarm). Participants (N = 19, undergraduates) identified alarm type, priority, and patient identity (patient 1 or 2) using conventional and multisensory alarms, while simultaneously completing a cognitively demanding task. Performance was based on reaction time (RT) and identification accuracy of alarm type and priority. Participants also reported their perceived workload. RT was significantly faster for the Control phase (p < 0.05). Participant performance in identifying alarm type, priority, and patient did not differ significantly between the three phase conditions (p = 0.87, 0.37, and 0.14 respectively). The Half multisensory phase produced the lowest mental demand, temporal demand, and overall perceived workload score. These data suggest that implementation of a multisensory alarm with alarm and patient information may decrease perceived workload without significant changes in alarm identification performance. Additionally, a ceiling effect may exist for multisensory stimuli, with only part of an alarm benefitting from multisensory integration.© 2023. The Author(s), under exclusive licence to Springer Nature B.V.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.