• Injury · Jul 2023

    Clockwise torque results in higher reoperation rates in left-sided femur fractures.

    • Jacobien H F Oosterhoff, Hidde Dijkstra, Aditya V Karhade, Rudolf W Poolman, Inger B Schipper, NelissenRob G H HRGHHDepartment of Orthopaedic Surgery, Leiden University Medical Center, Leiden, the Netherlands., Daphne van Embden, Ruurd L Jaarsma, Joseph H Schwab, Job N Doornberg, Marilyn Heng, and Bhavin Jadav.
    • Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA; Department of Engineering Systems and Services, Faculty Technology Policy Management, Delft University of Technology, Delft, the Netherlands.
    • Injury. 2023 Jul 1; 54 (7): 110757110757.

    PurposeEffects of clockwise torque rotation onto proximal femoral fracture fixation have been subject of ongoing debate: fixated right-sided trochanteric fractures seem more rotationally stable than left-sided fractures in the biomechanical setting, but this theoretical advantage has not been demonstrated in the clinical setting to date. The purpose of this study was to identify a difference in early reoperation rate between patients undergoing surgery for left- versus right-sided proximal femur fractures using cephalomedullary nailing (CMN).Materials And MethodsThe American College of Surgeons National Surgical Quality Improvement Program was queried from 2016-2019 to identify patients aged 50 years and older undergoing CMN for a proximal femoral fracture. The primary outcome was any unplanned reoperation within 30 days following surgery. The difference was calculated using a Chi-square test, and observed power calculated using post-hoc power analysis.ResultsIn total, of 20,122 patients undergoing CMN for proximal femoral fracture management, 1.8% (n=371) had to undergo an unplanned reoperation within 30 days after surgery. Overall, 208 (2.0%) were left-sided and 163 (1.7%) right-sided fractures (p=0.052, risk ratio [RR] 1.22, 95% confidence interval [CI] 1.00-1.50), odds ratio [OR] 1.23 (95%CI 1.00-1.51), power 49.2% (α=0.05).ConclusionThis study shows a higher risk of reoperation for left-sided compared to right-sided proximal femur fractures after CMN in a large sample size. Although results may be underpowered and statistically insignificant, this finding might substantiate the hypothesis that clockwise rotation during implant insertion and (postoperative) weightbearing may lead to higher reoperation rates.Level Of EvidenceTherapeutic level II.Copyright © 2023. Published by Elsevier Ltd.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…