• Cochrane Db Syst Rev · May 2023

    Review

    Videolaryngoscopy versus direct laryngoscopy for tracheal intubation in neonates.

    • Krithika Lingappan, Nicole Neveln, Jennifer L Arnold, Caraciolo J Fernandes, and Mohan Pammi.
    • Division of Neonatology, Department of Pediatrics, Children's Hospital of Philadelphia, Philadelphia, PA, USA.
    • Cochrane Db Syst Rev. 2023 May 12; 5 (5): CD009975CD009975.

    BackgroundEstablishment of a secure airway is a critical part of neonatal resuscitation in the delivery room and the neonatal intensive care unit. Videolaryngoscopy has the potential to facilitate successful endotracheal intubation, and decrease adverse consequences of a delay in airway stabilization. Videolaryngoscopy may enhance visualization of the glottis and intubation success in neonates. This is an update of a review first published in 2015, and updated in 2018.ObjectivesTo determine the effectiveness and safety of videolaryngoscopy compared to direct laryngoscopy in decreasing the time and attempts required for endotracheal intubation and increasing the success rate on first intubation attempt in neonates (0 to 28 days of age).Search MethodsIn November 2022, we updated the search for trials evaluating videolaryngoscopy for neonatal endotracheal intubation in CENTRAL, MEDLINE, Embase, CINAHL, and BIOSIS. We also searched abstracts of the Pediatric Academic Societies, clinical trials registries (www.Clinicaltrialsgov; www.controlled-trials.com), and reference lists of relevant studies.Selection CriteriaRandomized controlled trials (RCTs), quasi-RCTs, cluster-RCTs, or cross-over trials, in neonates (0 to 28 days of age), evaluating videolaryngoscopy with any device used for endotracheal intubation compared with direct laryngoscopy.Data Collection And AnalysisThree review authors performed data collection and analysis, as recommended by Cochrane Neonatal. Two review authors independently assessed studies identified by the search strategy for inclusion. We used the GRADE approach to assess the certainty of the evidence.Main ResultsThe updated search yielded 7786 references, from which we identified five additional RCTs for inclusion, seven ongoing trials, and five studies awaiting classification. Three studies were included in the previous version of the review. For this update, we included eight studies, which provided data on 759 intubation attempts in neonates. We included neonates of either sex, who were undergoing endotracheal intubation in international hospitals. Different videolaryngoscopy devices (including C-MAC, Airtraq, and Glidescope) were used in the studies. For the primary outcomes; videolaryngoscopy may not reduce the time required for successful intubation when compared with direct laryngoscopy (mean difference [MD] 0.74, 95% confidence interval [CI] -0.19 to 1.67; 5 studies; 505 intubations; low-certainty evidence). Videolaryngoscopy may result in fewer intubation attempts (MD -0.08, 95% CI -0.15 to 0.00; 6 studies; 659 intubations; low-certainty evidence). Videolaryngoscopy may increase the success of intubation at the first attempt (risk ratio [RR] 1.24, 95% CI 1.13 to 1.37; risk difference [RD] 0.14, 95% CI 0.08 to 0.20; number needed to treat for an additional beneficial outcome [NNTB] 7, 95% CI 5 to 13; 8 studies; 759 intubation attempts; low-certainty evidence).  For the secondary outcomes; the evidence is very uncertain about the effect of videolaryngoscopy on desaturation or bradycardia episodes, or both, during intubation (RR 0.94, 95% CI 0.38 to 2.30; 3 studies; 343 intubations; very-low certainty evidence). Videolaryngoscopy may result in little to no difference in the lowest oxygen saturations during intubation compared with direct laryngoscopy (MD -0.76, 95% CI -5.74 to 4.23; 2 studies; 359 intubations; low-certainty evidence). Videolaryngoscopy likely results in a slight reduction in the incidence of airway trauma during intubation attempts compared with direct laryngoscopy (RR 0.21, 95% CI 0.05 to 0.79; RD -0.04, 95% CI -0.07 to -0.01; NNTB 25, 95% CI 14 to 100; 5 studies; 467 intubations; moderate-certainty evidence). There were no data available on other adverse effects of videolaryngoscopy. We found a high risk of bias in areas of allocation concealment and performance bias in the included studies.Authors' ConclusionsVideolaryngoscopy may increase the success of intubation on the first attempt and may result in fewer intubation attempts, but may not reduce the time required for successful intubation (low-certainty evidence). Videolaryngoscopy likely results in a reduced incidence of airway-related adverse effects (moderate-certainty evidence). These results suggest that videolaryngoscopy may be more effective and potentially reduce harm when compared to direct laryngoscopy for endotracheal intubation in neonates. Well-designed, adequately powered RCTS are necessary to confirm the efficacy and safety of videolaryngoscopy in neonatal intubation.Copyright © 2023 The Cochrane Collaboration. Published by John Wiley & Sons, Ltd.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.