• Pain physician · May 2023

    Efficacy and Safety of a 3D-printed Guide Device During Percutaneous Kyphoplasty for the Treatment of Osteoporotic Vertebral Compression Fractures.

    • Hongwei Wang, Hongwen Gu, Bin Zheng, Yuanhang Zhao, Hong Yuan, Hailong Yu, and Liangbi Xiang.
    • Department of Orthopedics, General Hospital of Northern Theater Command of Chinese PLA, Shenyang, Liaoning, China.
    • Pain Physician. 2023 May 1; 26 (3): E143E153E143-E153.

    BackgroundDuring percutaneous kyphoplasty (PKP) for the treatment of osteoporotic vertebral compression fractures (OVCFs), repeated fluoroscopic images to adjust the puncture needle and inject the polymethylmethacrylate (PMMA) are critical steps. A method to further reduce the radiation dose would be of great value.ObjectivesTo assess the efficacy and safety of a 3D-printed guide device (3D-GD) for PKP in the treatment of OVCFs and compare the clinical efficacy and imaging outcomes of traditional bilateral PKP, bilateral PKP with 3D-GD and unilateral PKP with 3D-GD.Study DesignRetrospective study.SettingGeneral Hospital of Northern Theater Command of Chinese PLA.MethodsFrom September 2018 through March 2021, 113 patients diagnosed with monosegmental OVCFs underwent PKP. The patients were divided into 3 groups: traditional bilateral PKP (B-PKP group, 54 patients), bilateral PKP with 3D-GD (B-PKP-3D group, 28 patients) and unilateral PKP with 3D-GD (U-PKP-3D group, 31 patients). Their epidemiologic data, surgical indices, and recovery outcomes were collected during the follow-up period.ResultsThe operation time was significantly shorter in the B-PKP-3D group (52.5 ± 13.7 minutes) than in the B-PKP group (58.5 ± 9.5 minutes) (P = 0.044, t = 2.082). The operation time was significantly shorter in the U-PKP-3D group (43.6 ± 6.7 minutes) than in the B-PKP-3D group (52.5 ± 13.7 minutes) (P = 0.004, t = 3.109). The number of intraoperative fluoroscopy applications was significantly lower in the B-PKP-3D group (36.8 ± 6.1) than in the B-PKP group (44.8 ± 7.9) (P = 0.000, t = 4.621). The number of intraoperative fluoroscopy times was significantly lower in the U-PKP-3D group (23.2 ± 4.5) than in the B-PKP-3D group (36.8 ± 6.1) (P = 0.000, t = 9.778). The volume of injected PMMA was significantly lower in the U-PKP-3D group (3.7 ± 0.8 mL) than in the B-PKP-3D group (6.7 ± 1.7 mL) (P = 0.000, t = 8.766). The Visual Analog Scale (VAS) and Oswestry Disability Index (ODI) scores were significantly decreased one day after surgery in each group. However, there were no differences in postoperative VAS and ODI scores, anterior height or local kyphotic angle of the fractured vertebrae, PMMA leakage, or refracture of the vertebral body.LimitationsRelatively small sample size and short-term follow-up period.ConclusionThis new innovative 3D technique makes PKP safe and effective. The bilateral PKP with 3D-GD technique, even unilateral PKP with 3D-GD, has the advantages of accurate positioning, a short operation time, and reduced intraoperative fluoroscopy times to the patient and surgeon.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…