    Clinical and Analytic Accuracy of Simultaneously Acquired Hemoglobin Measurements: A Multi-Institution Cohort Study to Minimize Redundant Laboratory Usage.

    • Adam C Dziorny, Chloe Jones, Jennifer A Salant, Sherri Kubis, Martin S Zand, Heather A Wolfe, and Vijay Srinivasan.
    • Department of Pediatrics, University of Rochester School of Medicine, Rochester, NY.
    • Pediatr Crit Care Me. 2023 Nov 1; 24 (11): e520e530e520-e530.

    ObjectivesFrequent diagnostic blood sampling contributes to anemia among critically ill children. Reducing duplicative hemoglobin testing while maintaining clinical accuracy can improve patient care efficacy. The objective of this study was to determine the analytical and clinical accuracy of simultaneously acquired hemoglobin measurements with different methods.DesignRetrospective cohort study.SettingTwo U.S. children's hospitals.PatientsChildren (< 18 yr old) admitted to the PICU.InterventionsNone.Measurements And Main ResultsWe identified hemoglobin results from complete blood count (CBC) panels paired with blood gas (BG) panels and point-of-care (POC) devices. We estimated analytic accuracy by comparing hemoglobin distributions, correlation coefficients, and Bland-Altman bias. We measured clinical accuracy with error grid analysis and defined mismatch zones as low, medium, or high risk-based on deviance from unity and risk of therapeutic error. We calculated pairwise agreement to a binary decision to transfuse based on a hemoglobin value. Our cohort includes 49,004 ICU admissions from 29,926 patients, resulting in 85,757 CBC-BG hemoglobin pairs. BG hemoglobin was significantly higher (mean bias, 0.43-0.58 g/dL) than CBC hemoglobin with similar Pearson correlation ( R2 ) (0.90-0.91). POC hemoglobin was also significantly higher, but of lower magnitude (mean bias, 0.14 g/dL). Error grid analysis revealed only 78 (< 0.1%) CBC-BG hemoglobin pairs in the high-risk zone. For CBC-BG hemoglobin pairs, at a BG hemoglobin cutoff of greater than 8.0 g/dL, the "number needed to miss" a CBC hemoglobin less than 7 g/dL was 275 and 474 at each institution, respectively.ConclusionsIn this pragmatic two-institution cohort of greater than 29,000 patients, we show similar clinical and analytic accuracy of CBC and BG hemoglobin. Although BG hemoglobin values are higher than CBC hemoglobin values, the small magnitude is unlikely to be clinically significant. Application of these findings may reduce duplicative testing and decrease anemia among critically ill children.Copyright © 2023 by the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…