• Emerg Med J · Aug 2023

    Clinical Trial

    Evaluation of microMend wound closure device in repairing skin lacerations.

    • Tarek Nizami, Francesca Beaudoin, Selim Suner, Adam Aluisio, Reena A Bhatt, and Gregory D Jay.
    • Emergency Medicine, Rhode Island Hospital, Providence, Rhode Island, USA.
    • Emerg Med J. 2023 Aug 1; 40 (8): 564568564-568.

    BackgroundmicroMend, a novel microstaple skin closure device, may be able to close simple lacerations. This study aimed to evaluate the feasibility and acceptability of using microMend to close these wounds in the ED.MethodsThis was an open-label, single-arm clinical study conducted at two EDs within a large urban academic medical centre. Wounds closed with microMend underwent assessments performed at days 0, 7, 30 and 90. Photographs of treated wounds were rated by two plastic surgeons using a 100 mm visual analogue scale (VAS) and a wound evaluation scale (WES), which has a best possible score of 6. Participants rated pain during application and both participants and providers rated their satisfaction with the device.ResultsThirty-one participants were enrolled in the study: 48% were female and the mean age of participants was 45.6 (95% CI 39.1 to 52.1). The mean wound length was 2.35 cm (95% CI 1.77 to 2.92), with a range of 1-10 cm. Mean VAS and WES scores at day 90 as evaluated by two plastic surgeons were 84.1 mm (95% CI 80.2 to 87.9) and 4.91 (95% CI 4.54 to 5.29), respectively. The mean pain score with application of the devices was 7.28 mm (95% CI 2.88 to 11.68) on a scale of 0-100 mm using VAS. Local anaesthesia was used in 9 patients (29%, 95% CI 20.7 to 37.3) of participants (of whom 5 required deep sutures). Ninety per cent (90%) of participants rated their overall assessment of the device as excellent (74%) or good (16%) at day 90. There were no serious adverse events in any participants in the study.ConclusionmicroMend appears to be an acceptable alternative for closing skin lacerations in the ED, providing good cosmetic results, with high levels of satisfaction by patients and providers. Randomised trials are needed to compare microMend with other wound closure products.Trial Registration NumberNCT03830515.© Author(s) (or their employer(s)) 2023. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…