• Chinese Med J Peking · Jul 2008

    Randomized Controlled Trial Comparative Study

    Circulatory responses to nasotracheal intubation: comparison of GlideScope videolaryngoscope and Macintosh direct laryngoscope.

    • Fu-shan Xue, Xuan-ying Li, Qian-jin Liu, He-ping Liu, Quan-yong Yang, Ya-chao Xu, Xu Liao, and Yi Liu.
    • Department of Anesthesiology, Plastic Surgery Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100144, China. fruitxue@yahoo.com.cn
    • Chinese Med J Peking. 2008 Jul 20;121(14):1290-6.

    BackgroundThe GlideScope videolaryngoscope (GSVL) has been shown to have no special advantage over the Macintosh direct laryngoscope (MDL) in attenuating the circulatory responses to orotracheal intubation, but no study has compared the circulatory responses to nasotracheal intubation (NTI) using the two devices. This prospective randomized clinical study was designed to determine whether there was a clinically relevant difference between the circulatory responses to NTI with the GSVL and the MDL.MethodsSeventy-six adult patients were randomly allocated equally to the GSVL group and the MDL group. After induction of anesthesia, NTI was performed. Non-invasive blood pressure (BP) and heart rate (HR) were recorded before induction (baseline values) and immediately before intubation (post-induction values), at intubation and every minute for a further five minutes. During the observation, times required to reach the maximum values of systolic BP (SBP) and HR, times required for recovery of SBP and HR to postinduction values and incidence of SBP and HR percent changes > 30% of baseline values were also noted. The product of HR and systolic BP, i.e. rate pressure product (RPP), and the areas under SBP and HR vs. time curves (AUC(SBP) and AUC(HR)) were calculated.ResultsThe NTI with the GSVL resulted in significant increases in BP, HR and RPP compared to postinduction values, but these circulatory changes did not exceed baseline values. BPs at all measuring points, AUC(SBP), maximum values of BP and incidence of SBP percent increase > 30% of baseline value during the observation did not differ significantly between groups. However, HR and RPP at intubation and their maximum values, AUC(HR) and incidence of HR percent increase > 30% of baseline value were significantly higher in the MDL group than in the GSVL group. Times required for recovery of SBP and HR to postinduction values were significantly longer in the MDL group than in the GSVL group.ConclusionsThe pressor response to NTI with the GSVL and the MDL was similar, but the tachycardiac response to NTI was lesser and of a shorter duration when using a GSVL than when using an MDL.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.