• Spine · Aug 2023

    An Immunological and Biomechanical Comparison of PEEK-Zeolite and PEEK Interbody Fusion Devices.

    • Boyle C Cheng, Isaac Swink, Edward J McClain, Praveer S Vyas, Thomas Muzzonigro, Jake Carbone, Ali Zaidi, Jason D Long, Daniel T Altman, and Alexander K Yu.
    • Allegheny Health Network Research Institute, Pittsburgh, PA.
    • Spine. 2023 Aug 15; 48 (16): 117411801174-1180.

    Study DesignA laboratory study comparing polyether ether ketone (PEEK)-zeolite and PEEK spinal implants in an ovine model.ObjectiveThis study challenges a conventional spinal implant material, PEEK, to PEEK-zeolite using a nonplated cervical ovine model.Summary Of Background DataAlthough widely used for spinal implants due to its material properties, PEEK is hydrophobic, resulting in poor osseointegration, and elicits a mild nonspecific foreign body response. Zeolites are negatively charged aluminosilicate materials that are hypothesized to reduce this pro-inflammatory response when used as a compounding material with PEEK.Materials And MethodsFourteen skeletally mature sheep were, each, implanted with one PEEK-zeolite interbody device and one PEEK interbody device. Both devices were packed with autograft and allograft material and randomly assigned to one of 2 cervical disc levels. The study involved 2 survival time points (12 and 26 weeks) and biomechanical, radiographic, and immunologic endpoints. One sheep expired from complications not related to the device or procedure. A biomechanical evaluation was based on measures of segmental flexibility, using 6 degrees of freedom pneumatic spine tester. Radiographic evaluation was performed using microcomputed tomography scans in a blinded manner by 3 physicians. Levels of the pro-inflammatory cytokines, interleukin (IL)-1β, IL-6, and tumor necrosis factor-alpha at the implant, were quantified using immunohistochemistry.ResultsPEEK-zeolite and PEEK exhibited an equivalent range of motion in flexion extension, lateral bending, and axial torsion. A motion was significantly reduced for implanted devices at both time points as compared with native segments. Radiographic assessments of fusion and bone formation were similar for both devices. PEEK-zeolite exhibited lower levels of IL-1β ( P = 0.0003) and IL-6 ( P = 0.03).ConclusionPEEK-zeolite interbody fusion devices provide initial fixation substantially equivalent to PEEK implants but exhibit a reduced pro-inflammatory response. PEEK-zeolite devices may reduce the chronic inflammation and fibrosis previously observed with PEEK devices.Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…