- Jane Moon, Michael McPeck, Jeyanthan Jayakumaran, and Gerald C Smaldone.
- Pulmonary, Critical Care and Sleep Medicine Division, Department of Medicine, Stony Brook University Medical Center, Stony Brook, New York. Jane.moon@stonybrookmedicine.edu.
- Respir Care. 2023 Sep 1; 68 (9): 122112281221-1228.
BackgroundAerosolized drug delivery via high-flow nasal cannula (HFNC) decreases as gas flow is increased. To improve aerosol delivery, breath-enhanced jet nebulizer may increase aerosol output. This study tested that hypothesis and compared breath-enhanced jet nebulizer to vibrating mesh nebulizer technology.MethodsFirst, in an isolated circuit, breath-enhanced jet nebulizer and vibrating mesh nebulizer aerosol outputs were measured during simulated HFNC by using infused saline solution at rates of 5-60 mL/h. Limits were defined when nebulizer filling was detected. The devices were then tested by using 99mTc/saline solution to measure maximum rates of aerosol production. After the output experiments, drug delivery was measured in vitro by using a model that consisted of an HFNC circuit interfaced to a realistic 3-dimensional printed head. The 99mTc/saline solution was infused at rates of 5 to 60 mL/h for the breath-enhanced jet nebulizer and 5 to 20 mL/h for the vibrating mesh nebulizer with HFNC gas flows of 10 to 60 L/min. Aerosol delivery to the trachea was measured by using a shielded ratemeter, which defined the rate of drug delivery (µg NaCl/min).ResultsWith increasing gas flow, breath-enhanced jet nebulizer output increased to a maximum of 50 mL/h, the vibrating mesh nebulizer maximum was 12 mL/h. At HFNC gas flow of 60 L/min, breath-enhanced jet nebulizer delivered 3.16 to 316.8 µg NaCl/min, the vibrating mesh nebulizer delivered 23.5 to 61.7 µg NaCl/min. For infusion pump flows of 5 to 12 mL/h, the rate of drug delivery was independent of nebulizer type (P = .19) and dependent on infusion pump flow (P < .001) and gas flow (P < .001).ConclusionsIncreasing gas flow increased breath-enhanced jet nebulizer output, which demonstrated the effects of breath enhancement. At 60 L/min, breath enhanced jet nebulizer delivered up to 5 times more aerosol compared with conventional vibrating mesh nebulizer technology. Breath-enhanced jet nebulizer delivered a wide range of dose rates at all high flows. In patients who are critically ill, breath-enhanced jet nebulizer technology may allow titration of bedside dosing based on clinical response by simple adjustment of the infusion rate.Copyright © 2023 by Daedalus Enterprises.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.