• Spine · Oct 2023

    Biomechanical Computational Study of Pedicle Screw Position and Density in AIS Instrumentation.

    • Xiaoyu Wang, A Noelle Larson, David W Polly, and Carl-Eric Aubin.
    • Department of Mechanical Engineering, Polytechnique Montreal (Quebec), Canada.
    • Spine. 2023 Oct 15; 48 (20): 143614451436-1445.

    Study DesignComputer simulation of adolescent idiopathic scoliosis instrumentation.ObjectiveTo test the hypothesis that different screw densities would result in different apical vertebral rotation (AVR) corrections and bone-screw forces in adolescent idiopathic scoliosis instrumentation.Summary Of Background DataThe "Minimize Implants Maximize Outcomes" Clinical Trial revealed that the use of more versus fewer screws resulted in similar coronal plane correction for Lenke 1A curves. However, the biomechanical impact of screw density on transverse plane correction is still unclear. Further investigation is needed to determine if and how transverse plane correction is correlated with screw density.Patients And MethodsWe simulated apical vertebral derotation after segmental translation using patient-specific computer models of 30 patients from the "Minimize Implants Maximize Outcomes" Trial. For each case, 10 alternative screw patterns were tested with overall densities ranging between 1.2 and 2 screws per level fused, and local density at the 3 apical levels ranging between 0.7 and 2 (total: 600 simulations). Main thoracic (MT) Cobb angle, thoracic kyphosis (TK), AVR, and bone-screw forces were computed and compared.ResultsThe presenting MT (62 ± 11°; range: 45° to 86°), TK (27 ± 20°; -5° to 81°), and AVR (14±7°; -2° to 25°) were corrected through segmental translation to 22 ± 7° (10° to 41°), 26 ± 5° (18° to 45°), and 14 ± 7° (-4° to 26°). After apical vertebral derotation, they became 16 ± 8° (1° to 41°), 24 ± 4° (13° to 40°), and 4 ± 5° (-12° to 18°). There was no significant difference in MT among screw patterns; higher screw density had lower bone-screw forces ( P < 0.05). The apical vertebral derotation maneuver reduced AVR by an average of 70%, positively correlated with apical screw density ( r = 0.825, P < 0.05). There was no significant difference in TK.ConclusionScrew density had no significant effect on 3-dimensional correction through the primary segmental translation maneuver. Transverse plane correction through subsequent apical vertebral derotation was positively correlated with screw density at the apical levels ( r = 0.825, P < 0.05). Bone-screw forces were negatively correlated with overall screw density ( P < 0.05).Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…