• Neuromodulation · Jun 2024

    Review

    Adverse Events and Complications Associated With Vagal Nerve Stimulation: An Analysis of the Manufacturer And User Facility Device Experience Database.

    • Yuan Guang Lim, Justin Rui Xin Ker, Yee Leng Tan, Derrick W S Chan, David Chyi Yeu Low, Wai Hoe Ng, and Kai Rui Wan.
    • Department of Neurosurgery, National Neuroscience Institute, Singapore. Electronic address: yuanguang.lim@mohh.com.sg.
    • Neuromodulation. 2024 Jun 1; 27 (4): 781788781-788.

    ObjectiveDrug-resistant epilepsy (DRE) can have devastating consequences for patients and families. Vagal nerve stimulation (VNS) is used as a surgical adjunct for treating DRE not amenable to surgical resection. Although VNS is generally safe, it has its inherent complications. With the increasing number of implantations, adequate patient education with discussion of possible complications forms a critical aspect of informed consent and patient counseling. There is a lack of large-scale reviews of device malfunction, patient complaints, and surgically related complications available to date.Materials And MethodsComplications associated with VNS implants performed between 2011 and 2021 were identified through a search of the United States Food and Drug Administration Manufacturer And User Facility Device Experience (MAUDE) data base. We found three models on the data base, CYBERONICS, INC pulse gen Demipulse 103, AspireSR 106, and SenTiva 1000. The reports were classified into three main groups, "Device malfunction," "Patient complaints," and "Surgically managed complications."ResultsA total of 5888 complications were reported over the ten-year period, of which 501 reports were inconclusive, 610 were unrelated, and 449 were deaths. In summary, there were 2272 reports for VNS 103, 1526 reports for VNS 106, and 530 reports for VNS 1000. Within VNS 103, 33% of reports were related to device malfunction, 33% to patient complaints, and 34% to surgically managed complications. For VNS 106, 35% were related to device malfunction, 24% to patient complaints, and 41% to surgically managed complications. Lastly, for VNS 1000, 8% were device malfunction, 45% patient complaints, and 47% surgically managed complications.ConclusionWe present an analysis of the MAUDE data base for adverse events and complications related to VNS. It is hoped that this description of complications and literature review will help promote further improvement in its safety profile, patient education, and management of both patient and clinician expectations.Copyright © 2023 International Neuromodulation Society. Published by Elsevier Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…