• J. Thorac. Cardiovasc. Surg. · Feb 2024

    Expanded polytetrafluoroethylene conduits with curved and hand-sewn bileaflet designs for right ventricular outflow tract reconstruction.

    • Shunsuke Matsushima, Hironori Matsuhisa, Kohki Wakita, Takanori Tsujimoto, Naohisa Takagaki, Itsuro Honda, Yoshihiro Oshima, Osamu Kawanami, and Kenji Okada.
    • Department of Cardiovascular Surgery, Kobe Children's Hospital, Kobe, Japan; Division of Cardiovascular Surgery, Department of Surgery, Kobe University Graduate School of Medicine, Kobe, Japan. Electronic address: shunsuke.matsushima@gmail.com.
    • J. Thorac. Cardiovasc. Surg. 2024 Feb 1; 167 (2): 439449.e6439-449.e6.

    ObjectiveThis study reviewed the application of curved and bileaflet designs to pulmonary expanded polytetrafluoroethylene conduits with diameters of 10 to 16 mm and characterized this conduit on in vitro experiment, including particle image velocimetry.MethodsAll patients who received this conduit between 2010 and 2022 were evaluated. Three 16-mm conduits were tested in a circulatory simulator at different cardiac outputs (1.5-3.6 L/minute) and bending angles (130°-150°).ResultsFifty consecutive patients were included. The median operative body weight was 8.4 kg (range, 2.6-12 kg); 10-, 12-, 14-, and 16-mm conduits were used in 1, 4, 6, and 39 patients, respectively. In 34 patients, the conduit was implanted in a heterotopic position. The overall survival rate was 89% at 8 years with 3 nonvalve-related deaths. There were 10 conduit replacements; 5 16-mm conduits (after 8 years) and 1 12-mm conduit (after 6 years) due to conduit stenosis, and the remaining 4 for reasons other than conduit failure. Freedom from conduit replacement was 89% and 82% at 5 and 8 years, respectively. Linear mixed-effects models with echocardiographic data implied that 16-mm conduits were durable with a peak velocity <3.5 m/second and without moderate/severe regurgitation until the patient's weight reached 25 kg. In experiments, peak transvalvular pressure gradients were 11.5 to 25.5 mm Hg, regurgitant fractions were 8.0% to 14.4%, and peak Reynolds shear stress in midsystolic phase was 29 to 318 Pa.ConclusionsOur conduits with curved and bileaflet designs have acceptable clinical durability and proven hydrodynamic profiles, which eliminate valve regurgitation and serve as a reliable bridge to subsequent conduit replacement.Copyright © 2023 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…