• Medicine · Jun 2023

    Finite element analysis of minimally invasive nail placement and traditional nail placement in the treatment of lumbar 1 vertebral compression fracture.

    • Chunbo Huang, Chunling Zhang, Feng Su, Liu Su, Pengpeng Ma, Zhiguo Zong, Xin Zhang, Wei Li, and Ming Cai.
    • Department of Orthopaedics, Hebei North University, Zhangjiakou, China.
    • Medicine (Baltimore). 2023 Jun 30; 102 (26): e34145e34145.

    AbstractUsing the finite element analysis method to help us better understand the biomechanical changes of the spine after surgery and the changes in the stress distribution around the screw implantation area. The finite element model of L1 vertebral compression fracture was constructed by using a large number of finite element programs. On the fracture model, 2 kinds of internal fixation devices are set up, namely: the first type of 4 screws across the injured vertebra through the adjacent upper and lower vertebrae + transverse connector; the second type of 4 screws crosses the injured vertebra through the adjacent upper and lower vertebrae + non-transverse connector. To study the distribution of the maximum displacement and von Mises stress of the intramedullary pedicle screws and rods of the 2 types of internal fixation devices after implantation in the spine under certain loading conditions. In traditional open pedicle screw fixation, the maximum stress in the pedicle screw fixation system in the direction of 3D movement is higher than in percutaneous pedicle screw fixation. There is no significant difference in the Von Mises stress of the pedicle screw between the 2 procedures when the spine performs flexion-extension and lateral flexion activities. When the spine is rotating axially, the Von Mises stress of the pedicle screw in conventional open surgery is significantly less than that of the screw in percutaneous pedicle screw fixation. Traditional open internal fixation produces stress peaks of 891.7 MPa and 886.34 MPa at the transverse joint during axial rotation. Only when the spine is rotating in the axial direction, the maximum displacement of traditional open pedicle screw fixation is smaller than that of percutaneous pedicle screw fixation. There is no significant difference in the maximum displacement between the 2 procedures when the spine is moving in other directions. Traditional open pedicle screw fixation can strengthen the stability of the spine in the direction of axial rotation, and can also be greater to reduce the maximum stress of the pedicle screw axial rotation, so the clinical treatment of unstable fractures of the thoracolumbar spine instability is of great significance.Copyright © 2023 the Author(s). Published by Wolters Kluwer Health, Inc.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.