• Eur J Trauma Emerg Surg · Feb 2024

    Development of patient-specific osteosynthesis including 3D-printed drilling guides for medial tibial plateau fracture surgery.

    • Nick Assink, Miriam G E Oldhoff, Ten DuisKajK0000-0001-8920-8796Department of Trauma Surgery, University of Groningen, University Medical Center Groningen, HPC BA13, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands., Joep Kraeima, Job N Doornberg, Max J H Witjes, de VriesJean-Paul P MJPM0000-0002-2669-320XDepartment of Surgery, University Medical Center Groningen, Groningen, The Netherlands., Anne M L Meesters, and IJpmaFrank F AFFA0000-0002-9420-2732Department of Trauma Surgery, University of Groningen, University Medical Center Groningen, HPC BA13, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands..
    • Department of Trauma Surgery, University of Groningen, University Medical Center Groningen, HPC BA13, Hanzeplein 1, 9713 GZ, Groningen, The Netherlands. n.assink@umcg.nl.
    • Eur J Trauma Emerg Surg. 2024 Feb 1; 50 (1): 111911-19.

    PurposeA substantial proportion of conventional tibial plateau plates have a poor fit, which may result in suboptimal fracture reduction due to applied -uncontrolled- compression on the bone. This study aimed to assess whether patient-specific osteosyntheses could facilitate proper fracture reduction in medial tibial plateau fractures.MethodsIn three Thiel embalmed human cadavers, a total of six tibial plateau fractures (three Schatzker 4, and three Schatzker 6) were created and CT scans were made. A 3D surgical plan was created and a patient-specific implant was designed and fabricated for each fracture. Drilling guides that fitted on top of the customized plates were designed and 3D printed in order to assist the surgeon in positioning the plate and steering the screws in the preplanned direction. After surgery, a postoperative CT scan was obtained and outcome was compared with the preoperative planning in terms of articular reduction, plate positioning, and screw direction.ResultsA total of six patient-specific implants including 41 screws were used to operate six tibial plateau fractures. Three fractures were treated with single plating, and three fractures with dual plating. The median intra-articular gap was reduced from 6.0 (IQR 4.5-9.5) to 0.9 mm (IQR 0.2-1.4), whereas the median step-off was reduced from 4.8 (IQR 4.1-5.3) to 1.3 mm (IQR 0.9-1.5). The median Euclidean distance between the centre of gravity of the planned and actual implant was 3.0 mm (IQR: 2.8-3.7). The lengths of the screws were according to the predetermined plan. None of the screws led to screw penetration. The median difference between the planned and actual screw direction was 3.3° (IQR: 2.5-5.1).ConclusionThis feasibility study described the development and implementation of a patient-specific workflow for medial tibial plateau fracture surgery that facilitates proper fracture reduction, tibial alignment and accurately placed screws by using custom-made osteosynthesis plates with drilling guides.© 2023. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…