Acta Anaesthesiol Scand · Nov 2023
High-flow via a tracheostomy tube and speaking valve during weaning from mechanical ventilation and tracheostomy.
- Peter H Egbers, Anna-Liisa Sutt, Jenny E Petersson, Liza Bergström, and Eva Sundman.
- Medical Centre of Leeuwarden, Leeuwarden, The Netherlands.
- Acta Anaesthesiol Scand. 2023 Nov 1; 67 (10): 140314131403-1413.
BackgroundWeaning from mechanical ventilation and tracheostomy after prolonged intensive care consume enormous resources with optimal management not currently well described. Restoration of respiratory flow via the upper airway is essential and early cuff-deflation using a one-way valve (OWV) is recommended. However, extended OWV use may cause dry airways and thickened secretions which challenge the weaning process. High-flow therapy via the tracheostomy tube (HFT-T) humidifies inspired air and may be connected via an in-line OWV (HFT-T-OWV) alleviating these problems. We aim to provide clinical and experimental data on the safety of HFT-T-OWV along with a practical guide to facilitate clinical use during weaning from mechanical ventilation and tracheostomy.MethodsData on adverse events of HFT-T-OWV were retrieved from a quality register for patients treated at an intensive care rehabilitation center between 2019 and 2022. Benchtop experiments were performed to measure maximum pressures and pressure support generated by HFT-T-OWV at 25-60 L/min flow using two different HFT-T adapters (interfaces). In simulated airway obstruction using a standard OWV (not in-line) maximum pressures were measured with oxygen delivered via the side port at 1-3 L/min.ResultsOf 128 tracheostomized patients who underwent weaning attempts, 124 were treated with HFT-T-OWV. The therapy was well tolerated, and no adverse events related to the practice were detected. The main reason for not using HFT-T-OWV was partial upper airway obstruction using a OWV. Benchtop experiments demonstrated HFT-T-OWV maximum pressures <4 cmH2 O and pressure support 0-0.6 cmH2 O. In contrast, 1-3 L/min supplemental oxygen via a standard OWV caused pressures between 84 and 148 cmH2 O during simulated airway obstruction.ConclusionsCurrent study clinical data and benchtop experiments indicate that HFT-T-OWV was well tolerated and appeared safe. Pressure support was low, but humidification may enable extended use of a OWV without dry airway mucosa and thickened secretions. Results suggest the treatment could offer advantages to standard OWV use, with or without supplementary oxygen, as well as to HFT-T without a OWV, for weaning from mechanical ventilation and tracheostomy. However, for definitive treatment recommendations, randomized clinical trials are needed.© 2023 The Authors. Acta Anaesthesiologica Scandinavica published by John Wiley & Sons Ltd on behalf of Acta Anaesthesiologica Scandinavica Foundation.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.