-
- Sebastian Antes, Rene Moringlane, and Kajetan L von Eckardstein.
- Department of Neurosurgery, Westpfalz-Klinikum GmbH, Kaiserslautern, Germany. Electronic address: sebastian.antes@gmail.com.
- World Neurosurg. 2023 Oct 1; 178: 9610096-100.
BackgroundOne of the most common reasons for poor patient outcomes and revision surgery in spinal fusion is hardware failure. Screw loosening or pullout occurs in up to one-quarter of all cases. It is known that even small screw-rod misalignments can cause significant mechanical overloads during rod fixation, which can result in hardware failure. To address this crucial surgical step, a novel augmented reality-assisted software was developed to generate custom rod templates that are precisely adapted to the individual patient.MethodsThe novel software, which runs on a tablet, is used in spinal fusion surgery and is based on the use of a specific pedicle screw system, in which the polyaxial screw heads are connected to detachable guides. These guides can be recognized by the tablet camera and a light detection and ranging scanner. This image information is processed to determine the spatial positions of the screw heads and to calculate an ideally fitting rod template.ResultsThe calculated rod template is displayed in a 1-to-1 scale on the tablet screen. This template is used to cut and bend the rods of the pedicle screw system. Finally, the custom bent rod can be inserted into the screw heads without tension.ConclusionsThe augmented reality-assisted software is intended to give surgeons access to patient-specific intraoperative real-time data, helping them in bending rods that are more precisely adapted to the individual patient compared with the freehand technique.Copyright © 2023 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.