-
- Matthew H Brown, Samuel R Marcrom, Mayank P Patel, Richard A Popple, Roman L Travis, Andrew M McDonald, Kristen O Riley, James M Markert, Christopher D Willey, Markus Bredel, John B Fiveash, and Evan M Thomas.
- Department of Radiation Oncology, University of Maryland, Baltimore , Maryland , USA.
- Neurosurgery. 2023 Dec 1; 93 (6): 131313181313-1318.
Background And ObjectivesThere is wide variation in treatment planning strategy for central nervous system (CNS) stereotactic radiosurgery. We sought to understand what relationships exist between intratumor maximum dose and local control (LC) or CNS toxicity, and dosimetric effects of constraining hotspots on plan quality of multiple metastases volumetric modulated arc therapy radiosurgery plans.MethodsWe captured brain metastases from 2015 to 2017 treated with single-isocenter volumetric modulated arc therapy radiosurgery. Included tumors received single-fraction stereotactic radiosurgery, had no previous surgery or radiation, and available follow-up imaging. Our criterion for local failure was 25% increase in tumor diameter on follow-up MRI or pathologic confirmation of tumor recurrence. We defined significant CNS toxicity as Radiation Therapy Oncology Group irreversible Grade 3 or higher. We performed univariate and multivariate analyses evaluating factors affecting LC. We examined 10 stereotactic radiosurgery plans with prescriptions of 18 Gy to all targets originally planned without constraints on the maximum dose within the tumor. We replanned each with a constraint of Dmax 120%. We compared V50%, mean brain dose, and Dmax between plans.ResultsFive hundred and thirty tumors in 116 patients were available for analysis. Median prescription dose was 18 Gy, and median prescription isodose line (IDL) was 73%. Kaplan-Meier estimate of 12-month LC only tumor volume (HR 1.43 [1.22-1.68] P < .001) was predictive of local failure on univariate analysis; prescription IDL and histology were not. In multivariate analysis, tumor volume impacted local failure (HR 1.43 [1.22-1.69] P < .001) but prescription IDL did not (HR 0.95 [0.86-1.05] P = .288). Only a single grade 3 and 2 grade 4 toxicities were observed; tumor volume was predictive of CNS toxicity (HR 1.58 [1.25-2.00]; P < .001), whereas prescription IDL was not (HR 1.01 [0.87-1.17] P = .940).ConclusionThe prescription isodose line had no impact on local tumor control or CNS toxicity. Penalizing radiosurgery hotspots resulted in worse radiosurgery plans with poorer gradient. Limiting maximum dose in gross tumor causes increased collateral exposure to surrounding tissue and should be avoided.Copyright © 2023 The Author(s). Published by Wolters Kluwer Health, Inc. on behalf of the Congress of Neurological Surgeons.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.