    BackgroundThe precision of quasi-static airway driving pressure (ΔP) assessed in pressure support ventilation (PSV) as a surrogate of tidal lung stress is debatable because persistent muscular activity frequently alters the readability of end-inspiratory holds. In this study, we used strict criteria to discard excessive muscular activity during holds and assessed the accuracy of ΔP in predicting global lung stress in PSV. Additionally, we explored whether the physiological effects of high PEEP differed according to the response of respiratory system compliance (CRS).MethodsAdults with ARDS undergoing PSV were enrolled. An esophageal catheter was inserted to calculate lung stress through transpulmonary driving pressure (ΔPL). ΔP and ΔPL were assessed in PSV at PEEP 5, 10, and 15 cm H2O by end-inspiratory holds. CRS was calculated as tidal volume (VT)/ΔP. We analyzed the effects of high PEEP on pressure-time product per minute (PTPmin), airway pressure at 100 ms (P0.1), and VT over PTP per breath (VT/PTPbr) in subjects with increased versus decreased CRS at high PEEP.ResultsEighteen subjects and 162 end-inspiratory holds were analyzed; 51/162 (31.5%) of the holds had ΔPL ≥ 12 cm H2O. Significant association between ΔP and ΔPL was found at all PEEP levels (P < .001). ΔP had excellent precision to predict ΔPL, with 15 cm H2O being identified as the best threshold for detecting ΔPL ≥ 12 cm H2O (area under the receiver operating characteristics 0.99 [95% CI 0.98-1.00]). CRS changes from low to high PEEP corresponded well with lung compliance changes (R2 0.91, P < .001) When CRS increased, a significant improvement of PTPmin and VT/PTPbr was found, without changes in P0.1. No benefits were observed when CRS decreased.ConclusionsIn subjects with ARDS undergoing PSV, high ΔP assessed by readable end-inspiratory holds accurately detected potentially dangerous thresholds of ΔPL. Using ΔP to assess changes in CRS induced by PEEP during assisted ventilation may inform whether higher PEEP could be beneficial.Copyright © 2023 by Daedalus Enterprises.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…