Comparative Study
Reproducibility of thermodilution cardiac output determination in critically ill patients: comparison between bolus and continuous method.
- Y Le Tulzo, M Belghith, P Seguin, J Dall'Ava, M Monchi, R Thomas, and J F Dhainaut.
- Department of Medical Intensive Care Unit, Pontchaillou University-Hospital, Rennes, France.
- J Clin Monit. 1996 Sep 1;12(5):379-85.
ObjectiveA semi-continuous thermodilution method (CCO) was recently developed to measure cardiac output with less risk of bacterial contamination, fluid overload, and user-induced errors than the classical bolus technique (BCO). Previous comparison between these two methods showed negligible bias. However, large limits of agreement suggest that the two methods are not interchangeable. We hypothesized that this poor agreement may be due to differences in reproducibility.MethodsIn 23 critically ill patients, 369 paired measurements of CCO and BCO were compared (range of cardiac outputs: 2.8 to 16 L/min). The reproducibility of BCO and CCO methods was evaluated on a sample of 205 and 209 determinations, respectively.ResultsThe comparison between the CCO and the BCO methods confirmed previous results: i.e., small bias (-0.39 L/min) and large limits of agreement (-2.06 to +1.28 L/min). Reproducibility showed no bias for either the CCO or the BCO method. Limits of reproducibility agreement between repeated determinations were approximately 50% less for CCO than for BCO method: respectively -0.87 to +0.82 L/min for the CCO method and -1.56 to +1.37 L/min for the BCO method. Consequently, the threshold necessary to ascertain that the difference between two measurements was not due to the internal variability of the method (3 x SEM) was 0.39 for the CCO method and 0.75 L/min for the BCO method.ConclusionDifferences in reproducibility may explain the poor agreement between the CCO and BCO methods. The better reproducibility of the CCO method allows the detection of smaller variations in cardiac output and suggests the superiority of this new method.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.