Intensive care medicine · Feb 1999
Randomized Controlled Trial Comparative Study Clinical TrialContinuous thermodilution cardiac output: clinical validation against a reference technique of known accuracy.
- E R Schmid, D Schmidlin, M Tornic, and B Seifert.
- Division of Cardiovascular Anaesthesia, Institute of Anaesthesiology, University Hospital of Zurich, Switzerland. edith.schmid@ifa.usz.ch
- Intensive Care Med. 1999 Feb 1;25(2):166-72.
ObjectiveTo evaluate the accuracy and precision of continuous thermodilution (CCO) by using a validated bolus thermodilution (BCO) reference technique as criterion standard.DesignUnder circulatory steady state conditions, a CCO system (Vigilance, software versions 4.35 and 4.39) was validated with regard to CCO as well as iced and room temperature BCO.SettingIntensive care unit at a university hospital.PatientsMethod comparison was conducted in 56 cardiac surgical patients, 28 patients being allocated to one of the two software versions, and 14 within each group to either iced or room temperature BCO.Measurements And ResultsCCO readings were registered in duplicate before and after three to five bolus injections conducted with both the Vigilance and reference systems. Iced BCO showed excellent agreement between the Vigilance and reference systems, yielding SDs of bias of 0.41 and 0.37 l/min and linear correlation coefficients (r) of 0.97 and 0.96. With room temperature BCO, agreement was significantly less. CCO, irrespective of software version, showed higher SDs of bias (0.90 and 0.84 l/min) and lower r values (0.84 and 0.81) than iced BCO (p < 0.0001). CCO measurements with software version 4.39 yielded a similar SD of bias to that with room temperature BCO.ConclusionDecreased precision of CCO as compared to iced BCO may, in clinical settings, be outweighed by the advantages of automated and continuous monitoring. Under research conditions, however, iced BCO remains the method of choice.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.