• Cochrane Db Syst Rev · Jan 2013

    Review Meta Analysis Comparative Study

    Orthodontic treatment for distalising upper first molars in children and adolescents.

    • Safa Jambi, Badri Thiruvenkatachari, Kevin D O'Brien, and Tanya Walsh.
    • School of Dentistry, The University of Manchester, Higher Cambridge Street, Manchester, UK, M15 6FH.
    • Cochrane Db Syst Rev. 2013 Jan 1;10:CD008375.

    BackgroundWhen orthodontic treatment is provided with fixed appliances, it is sometimes necessary to move the upper molar teeth backwards (distalise) to create space or help to overcome anchorage requirements. This can be achieved with the use of extraoral or intraoral appliances. The most common appliance is extraoral headgear, which requires considerable patient co-operation. Further, reports of serious injuries have been published. Intraoral appliances have been developed to overcome such shortcomings. The comparative effects of extraoral and intraoral appliances have not been fully evaluated.ObjectivesTo assess the effects of orthodontic treatment for distalising upper first molars in children and adolescents.Search MethodsWe searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 10 December 2012), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2012, Issue 11), MEDLINE via OVID (1946 to 10 December 2012) and EMBASE via OVID (1980 to 10 December 2012). No restrictions were placed on the language or date of publication when searching the electronic databases.Selection CriteriaRandomised clinical trials involving the use of removable or fixed orthodontic appliances intended to distalise upper first molars in children and adolescents.Data Collection And AnalysisWe used the standard methodological procedures expected by The Cochrane Collaboration. We performed data extraction and assessment of the risk of bias independently and in duplicate. We contacted authors to clarify the inclusion criteria of the studies.Main ResultsTen studies, reporting data from 354 participants, were included in this review, the majority of which were carried out in a university dental hospital setting. The studies were published between 2005 and 2011 and were conducted in Europe and in Brazil. The age range of participants was from nine to 15 years, with an even distribution of males and females in seven of the studies, and a slight predominance of female patients in three of the studies. The quality of the studies was generally poor; seven studies were at an overall high risk of bias, three studies were at an unclear risk of bias, and we judged no study to be at low risk of bias.We carried out random-effects meta-analyses as appropriate for the primary clinical outcomes of movement of upper first molars (mm), and loss of anterior anchorage, where there were sufficient data reported in the primary studies. Four studies, involving 159 participants, compared a distalising appliance to an untreated control. Meta-analyses were not undertaken for all primary outcomes due to incomplete reporting of all summary statistics, expected outcomes, and differences between the types of appliances. The degree and direction of molar movement and loss of anterior anchorage varied with the type of appliance. Four studies, involving 150 participants, compared a distalising appliance versus headgear. The mean molar movement for intraoral distalising appliances was -2.20 mm and -1.04 mm for headgear. There was a statistically significant difference in mean distal molar movement (mean difference (MD) -1.45 mm; 95% confidence interval (CI) -2.74 to -0.15) favouring intraoral appliances compared to headgear (four studies, high or unclear risk of bias, 150 participants analysed). However, a statistically significant difference in mean mesial upper incisor movement (MD 1.82 mm; 95% CI 1.39 to 2.24) and overjet (fixed-effect: MD 1.64 mm; 95% CI 1.26 to 2.02; two studies, unclear risk of bias, 70 participants analysed) favoured headgear, i.e. there was less loss of anterior anchorage with headgear. We reported direct comparisons of intraoral appliances narratively due to the variation in interventions (three studies, high or unclear risk of bias, 93 participants randomised). All appliances were reported to provide some degree of distal movement, and loss of anterior anchorage varied with the type of appliance.No included studies reported on the incidence of adverse effects (harm, injury), number of attendances or rate of non-compliance.Authors' ConclusionsIt is suggested that intraoral appliances are more effective than headgear in distalising upper first molars. However, this effect is counteracted by loss of anterior anchorage, which was not found to occur with headgear when compared with intraoral distalising appliance in a small number of studies. The number of trials assessing the effects of orthodontic treatment for distilisation is low, and the current evidence is of low or very low quality.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…