• Injury · Nov 2023

    Lateral cortical notching facilitates dynamization of proximal femoral nailing - A finite element analysis.

    • Nico Hinz, Katrin Stacenko, Christian Lutz, Arndt-Peter Schulz, and Robert Wendlandt.
    • Department of Trauma Surgery, Orthopaedics and Sports Traumatology, BG Trauma Hospital Hamburg, Bergedorfer Strasse 10, Hamburg 21033, Germany. Electronic address: n.hinz@bgk-hamburg.de.
    • Injury. 2023 Nov 1; 54 (11): 111009111009.

    IntroductionDynamization of proximal femoral nailing by removal of distal interlocking is one of the recommended treatment options for nonunions of femur fractures. However, in certain inter-/subtrochanteric fractures, gliding of the nail along the femoral shaft is blocked by lateral femoral cortical support of the lag screw. For these cases, Biber et al. proposed lateral cortical notching (LCN), in which the supporting lateral bone is removed. This study investigates the biomechanical effect of LCN on gliding of proximal femoral nailing and stress distribution at the bone/implant interface.Materials And MethodsIn this finite element analysis a three-dimensional model of an unstable intertrochanteric fracture with proximal femoral nailing without distal interlocking was simulated using the FebioStudio software suite. To simulate LCN, the lag screw hole was lengthened to 15.34 mm at the lateral cortex. Displacement of the nail along the femoral shaft axis and von Mises stress distribution were compared between LCN model and standard implantation model.ResultsDisplacement of the nail along the femoral shaft axis was higher in the LCN model than in the standard implantation model (0.48 mm vs. 0.07 mm). Highest von Mises stresses of 176-178 MPa at the implant and of 52-81 MPa at the proximal femur were detected. Maximum von Mises stresses of the implant were comparable at all sides, except for a reduced von Mises stress at the lateral inferior side in the LCN model (80 vs. 102 MPa). At the inferior lateral screw hole and the anterior/posterior lateral screw hole maximum von Mises stress was reduced in the LCN model (2 vs. 49 MPa and 52 vs. 81 MPa), whereas the maximum von Mises stress at the inferior medial screw hole was higher in the LCN model than in the standard implantation model (53 vs. 27 MPa).ConclusionsLateral cortical notching facilitates gliding of a distally dynamized proximal femoral nail along the femoral shaft axis in intertrochanteric fractures. Additionally, the lack of lateral cortical bone support at the lag screw reduces von Mises stress at the bone/implant interface and thus could lower the risk for implant breakage and peri‑implant fractures.Copyright © 2023 The Authors. Published by Elsevier Ltd.. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…