    Improving the reachability of contact aspiration for acute ischemic stroke using a new delivery assist catheter.

    • Hiroaki Neki, Yuichi Mochizuki, Yoshinobu Kamio, and Kazuhiko Kurozumi.
    • Department of Neurosurgery, Hamamatsu University School of Medicine, Hamamatsu, Shizuoka, Japan. Electronic address: neki04@hama-med.ac.jp.
    • World Neurosurg. 2023 Nov 1; 179: e510e514e510-e514.

    ObjectiveThis study aimed to improve the reachability of large lumen catheter for contact aspiration during acute ischemic stroke by a new delivery assist catheter.MethodsThis study included 58 patients with large-vessel stroke treated using endovascular procedures at our institution and affiliated hospitals between July 2021 and January 2023. Contact aspiration, especially contact aspiration using nonpenetrating of thrombus (CANP) technique, was adopted as first-line thrombectomy for localized internal carotid artery, middle cerebral artery proximal (M1 segment), and basilar artery without tandem occlusion in acute stroke. The new delivery assist catheter (AXS Offset catheter, Stryker, Fremont, CA, USA) was standardized after its release. Results of this improved contact aspiration technique using the new delivery assist catheter, including reachability, procedure time, and first-pass effect, were compared with conventional catheters.ResultsOf the 58 patients, 43 underwent only thrombectomy for acute embolic stroke. CANP technique was attempted on 25 patients (25/43, 58.1%). Of these, a normal inner catheter (inner diameter: 0.021 or 0.027 inches) and the new delivery assist catheter were used on 10 (10/25, 40%) and 15 (15/25, 60%) patients, respectively. An aspiration catheter reached the thrombus for 5 patients (5/10, 50%) and 14 patients (14/15 93.3%) in the normal and new delivery assist catheter groups, respectively (P = 0.023). There was no significant difference in the results of contact aspiration due to the delivery catheter.ConclusionsThe new delivery assist catheter improved the reachability of the aspiration catheter to the thrombus and is an effective device for performing CANP technique.Copyright © 2023 Elsevier Inc. All rights reserved.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.