-
Rev Assoc Med Bras (1992) · Jan 2023
American Thyroid Association and Thyroid Imaging Reporting and Data System developed by the American College of Radiology: which one is better at predicting malignancy risk?
- Marina Nogueira de Andrade, Julia Rodrigues Costa, Larissa Murici Sousa, Luiz Felipe Guimarães Gualberto Moreira, Rayla Felizardo Oliveira, Maria Carolina Barbosa Álvares, and Flávia Coimbra Pontes Maia.
- Santa Casa de Belo Horizonte - Belo Horizonte (MG), Brazil.
- Rev Assoc Med Bras (1992). 2023 Jan 1; 69 (10): e20221694e20221694.
ObjectiveThe aim of this study was to compare the capacity of American Thyroid Association and Thyroid Imaging Reporting and Data System developed by the American College of Radiology in predicting malignancy risk of thyroid nodules and to verify which one is better at avoiding unnecessary fine needle aspiration.MethodsThis was a cross-sectional study with 565 thyroid nodules, followed at a tertiary care hospital, in an iodine-replete area. Those were classified as American Thyroid Association and Thyroid Imaging Reporting and Data System developed by the American College of Radiology systems and stratified according to the Bethesda classification of fine needle aspiration. The values of sensibility, specificity, positive predictive value, and negative predictive value accuracy were calculated. Also, the percentage of unnecessary biopsies was presented.ResultsThe mean age of the individuals was 58.2±13.5 [26-90] years for benign nodules and 41.7±15.6 [23-66] years for malignant nodules (p=0.002). Regarding gender, 92.6% (n=150) of the individuals with benign nodules and 85.7% (n=06) with malignant nodules were females (p=0.601). For American Thyroid Association, 90.9% of sensibility, 51.4% of specificity, 52.6% of accuracy, 10.2% of positive predictive value, and 98.9% of negative predictive value were found. For Thyroid Imaging Reporting and Data System developed by the American College of Radiology, 90.9% of sensibility, 49.7% of specificity, 52.1% of accuracy, 9.9% of positive predictive value, and 98.9% of negative predictive value were found. .Notably, 12.3% of unnecessary fine needle aspiration were found in American Thyroid Association and 44.4% were found in Thyroid Imaging Reporting and Data System developed by the American College of Radiology.ConclusionBoth Thyroid Imaging Reporting and Data System developed by the American College of Radiology and American Thyroid Association are able to predict the malignancy risk of thyroid nodules. Thyroid Imaging Reporting and Data System developed by the American College of Radiology was better at avoiding unnecessary fine needle aspiration.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.