• Anesthesia and analgesia · Mar 2010

    Detection of carbon monoxide during routine anesthetics in infants and children.

    • Richard J Levy, Viviane G Nasr, Ozzie Rivera, Renee Roberts, Michael Slack, Joshua P Kanter, Kanishka Ratnayaka, Richard F Kaplan, and Francis X McGowan.
    • Division of Anesthesiology and Pain Medicine, Children's National Medical Center, 111 Michigan Ave., NW, Washington, DC 20010, USA. rlevy@cnmc.org
    • Anesth. Analg. 2010 Mar 1;110(3):747-53.

    BackgroundCarbon monoxide (CO) can be produced in the anesthesia circuit when inhaled anesthetics are degraded by dried carbon dioxide absorbent and exhaled CO can potentially be rebreathed during low-flow anesthesia. Exposure to low concentrations of CO (12.5 ppm) can cause neurotoxicity in the developing brain and may lead to neurodevelopmental impairment. In this study, we aimed to quantify the amount of CO present within a circle system breathing circuit during general endotracheal anesthesia in infants and children with fresh strong metal alkali carbon dioxide absorbent and define the variables associated with the levels detected.MethodsFifteen infants and children (aged 4 months to 8 years) undergoing mask induction followed by general endotracheal anesthesia were evaluated in this observational study. CO was measured in real time from the inspiratory limb of the anesthesia circuit every 5 minutes for 1 hour during general anesthesia. Carboxyhemoglobin (COHb) levels were measured at the 1-hour time point and compared with baseline.ResultsCO was detected in all patients older than 2 years (0-18 ppm, mean 3.7 +/- 4.8 ppm) and rarely detected in patients younger than 2 years (0-2 ppm, mean 0.2 +/- 0.6 ppm). Only the relationship between CO concentration and fresh gas flow to minute ventilation ratio (FGF:(.)VE) remained significant after adjustment in longitudinal regression analysis (P < 0.001). Although not powered to determine such a relationship, CO levels were weakly associated with the use of desflurane and female sex. There was no significant association between CO concentration and anesthetic concentration. Baseline COHb levels were higher in children younger than 2 years and decreased significantly at the 1-hour time point compared with baseline and children older than 2 years. However, COHb levels increased significantly from baseline in a predictable manner consistent with CO exposure in children older than 2 years. FGF:(.)VE correlated significantly with change in COHb using simple linear regression (r = 0.62; P < 0.02).ConclusionsCO was detected routinely during general anesthesia in infants and children when FGF:(.)VE was <1. Peak CO levels measured in the anesthesia breathing circuit were in the range thought to impair the developing brain. Further study is required to identify the source of CO detected (CO produced by degradation of volatile anesthetic versus rebreathing CO from endogenous sources or both). However, these findings suggest that avoidance of low-flow anesthesia will prevent rebreathing of exhaled CO, and use of carbon dioxide absorbents that lack strong metal hydroxide could limit inspired CO if detection was attributable to degradation of volatile anesthetic.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…