-
Annals of Saudi medicine · Jan 2013
Randomized Controlled TrialFertility and pregnancy outcomes following resectoscopic septum division with and without intrauterine balloon stenting: a randomized pilot study.
- Basim Fouad Abu Rafea, George Angelos Vilos, Ayman Mohamad Oraif, Stephen George Power, Jackie Hollet Cains, and Angelos George Vilos.
- Obstetrics and Gynecology Department, King Saud University, Riyadh, Saudi Arabia. baburafea@ksu.edu.sa
- Ann Saudi Med. 2013 Jan 1; 33 (1): 343934-9.
Background And ObjectivesAlthough uterine stenting is performed routinely following hysteroscopic metroplasty, we were unable to find any evidence documenting its value with regards to septum reformation and/or obstetrical performance. To evaluate the benefits of intrauterine Foley catheter/balloon splinting after resectoscopic septum division on septum reformation, fertility, and pregnancy outcomes.Design And SettingProspective, randomized controlled pilot study (Canadian Task Force Classification I) conducted in university affiliated teaching hospital.Patients And MethodsTwenty-eight women with infertility and/or adverse pregnancy outcomes diagnosed with intrauterine septum were randomized into having a No. 14 pediatric Foley catheter/balloon for 5 days (n=13) vs. no balloon (n=15) following resectoscopic septum division. None of the patients received preoperative endometrial thinning, antibiotic prophylaxis or adjuvant postoperative hormone therapy. All uterine septa were divided under general anaesthesia using a 26 F (9 mm) resectoscope with a monopolar electrical knife using glycine irrigant solution (1.5%) and 120 watts of power of low voltage (cut) waveform.ResultsThe median age (range) was 29 years (23-38) and 32 years (22-40), respectively (P=.59). The groups were comparable by age, past obstetrical performance and comorbidities including endometriosis stage I-IV in 3 and 4 women, in the catheter/balloon and balloon group, respectively, and one in each group of polycystic ovarian syndrome and Crohn disease and one case of tubal obstruction in the balloon group. There were no intra- or postoperative complications. At 3 months, a hysterosalpingogram was done in 10 (77%) and 13 (87%) women, respectively, the results of which were normal. At 12-18 months, 1 woman in the balloon and 3 in the control group were not trying to conceive and 1 in each group had not conceived. Of the remaining women, 11 (92%) in each group had conceived and pregnancy outcomes included spontaneous abortion 3 (25%) and 4 (33.3%), ectopic pregnancy 0 and 1, second trimester loss 1 (8.3%) and 0 and term pregnancy 8 (66.6%) in both groups. Conception through assisted reproductive technology occurred in 2 and 1 woman, respectively.ConclusionsFollowing resectoscopic septum division with monopolar knife electrode, splinting the uterine cavity with Foley catheter provided no advantage in septum reformation, clinical pregnancy rate, and pregnancy outcomes.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.