• J Clin Monit Comput · Apr 2024

    Accuracy and clinical utility of heart rate variability derived from a wearable heart rate monitor in patients undergoing major abdominal surgery.

    • James Yang and Erez Ben-Menachem.
    • School of Clinical Medicine, Faculty of Medicine and Health, St Vincent's Healthcare Clinical Campus, UNSW Sydney, Sydney, Australia.
    • J Clin Monit Comput. 2024 Apr 1; 38 (2): 433443433-443.

    AbstractLow heart rate variability (HRV) can potentially identify patients at risk of intraoperative hypotension. However, it is unclear whether cheaper, readily accessible consumer heart rate (HR) monitors can provide similar utility to clinical Holter electrocardiograph (ECG) monitors. The objectives of this study were (1) to assess the validity of using the Polar H10 HR monitor as an alternative to a clinical Holter ECG and (2) to test total power (TP) as a predictor of intraoperative hypotension. The primary outcome was the level of agreement between Polar H10 and Holter ECG. Twenty-three patients undergoing major abdominal surgery with general anesthesia had 5-minute HR recordings taken concurrently with both devices during a pre-anesthetic consultation. Agreement between Polar H10 and Holter ECG was compared via Bland-Altman analysis and Lin's Concordance Correlation Coefficient. Patients were divided into groups based on TP <  500 m s 2 and TP >  500 m s 2 . Intraoperative hypotension was defined as MAP < 60 mmHg, systolic blood pressure < 80 mmHg, or 35% decrease in MAP from baseline. There was substantial agreement between Polar H10 and Holter ECG for average R-R interval, TP and other HRV indices. Reduced TP (< 500  ms 2 ) had a high sensitivity (80%) and specificity (100%) in predicting intraoperative hypotension. Patients with reduced TP were significantly more likely to require vasoactive drugs to maintain blood pressure.The substantial agreement between Polar H10 and Holter ECG may justify its use clinically. The use of preoperative recordings of HRV has the potential to become part of routine preoperative assessment as a useful screening tool to predict hemodynamic instability in patients undergoing general anesthesia.© 2023. The Author(s), under exclusive licence to Springer Nature B.V.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.