• Anaesth Intensive Care · Dec 2000

    Do antisiphon valves reduce flow irregularities during vertical displacement of infusion pump systems?

    • M Weiss, J Fischer, T Neff, G Schulz, and O Bänziger.
    • Department of Intensive Care and Neonatology, University Children's Hospital, Zurich, Switzerland.
    • Anaesth Intensive Care. 2000 Dec 1;28(6):680-3.

    AbstractVertical displacement of syringe pumps may cause irregular drug delivery due to hydrostatic pressure changes in the infusion line. The extent of flow fluctuations depends on the internal compliance of infusion lines, syringes and syringe pumps. We evaluated whether pressure regulation by antisiphon valves (ASV) reduces the flow variation during vertical displacement of 50 ml standard syringes and infusion pumps. An infusion assembly comprising a standard 50 ml BD Plastipak or a 50 ml Fresenius syringe, with syringe pump and 2 m low compliance infusion line was used for in vitro measurement of fluid delivery. The assembly was tested without ASV, and with two ASVs of differing operating pressure (ASV:75: valve opening pressure = 75 mmHg; ASV:155, 155 mmHg). Retrograde aspiration volume, zero-drug delivery time and valve opening bolus were determined after lowering the syringe pump by 50 cm. After elevating the syringe pump to its initial position the ensuing infusion bolus was recorded. Without an antisiphon valve the observed zero-drug delivery times after lowering the syringe pump were (mean +/- SD) 2.4 +/- 0.2 min using the BD Plastipak syringe and 4.09 +/- 0.55 min using the Fresenius syringe. Introduction of the antisiphon valve prolonged the zero drug delivery time 58% (ASV:75) and 88% (ASV:155) in the BD Plastipak syringe assembly and 43% (ASV:75) and 81% (ASV:155) in the Fresenius syringe assembly (P < 0.001). Antisiphon valves worsen flow irregularities caused by vertical displacement of syringe pumps and when used with delivery of concentrated inotropic drugs at low infusion rates, they may aggravate haemodynamic consequences of inconstant drug delivery.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

Want more great medical articles?

Keep up to date with a free trial of metajournal, personalized for your practice.
1,694,794 articles already indexed!

We guarantee your privacy. Your email address will not be shared.