- M Weiss, M I Hug, T Neff, and J Fischer.
- Department of Anaesthesia, University Children's Hospital, Zurich, Switzerland. markus.weiss@kispi.unizh.ch
- Can J Anaesth. 2000 Oct 1;47(10):1031-5.
PurposeTo evaluate the effect of syringe size and infusion rate on drug delivery after vertical displacement of syringe pumps.MethodsFour syringes (10 ml, 20 ml, 30 ml, 50 ml) were studied at three infusion speeds (2 ml x hr(-1), 1 ml x hr(-1) and 0.5 ml x hr(-1)). Fluid delivery was measured gravimetrically using an electronic balance. Aspiration volume (amount of fluid retracted into the syringe-infusion line assembly) and zero-drug delivery time (time between the lowering of the syringe pump and reattainment of the initial weight) were determined after lowering the syringe pump 130 cm or 50 cm. Then, infusion bolus was measured after elevating the pump to its initial position. Syringe compliance was calculated from the occlusion release bolus at an occlusion pressure of 300 mmHg.ResultsZero-drug delivery time, aspiration volume and infusion bolus increased with syringe size (P < 0.0001). At 0.5 ml x hr(-1), a zero-drug delivery time of 29.7 +/- 0.6 min was recorded for the 50 ml syringe and 5.5 +/- 0.15 min for the 10 ml syringe. As infusion rates increased, zero-drug delivery times decreased following a 1/x ratio. Zero-drug delivery time highly correlated with calculated syringe compliance (Pearson's r = 0.97, P < 0.001), which was closely related to syringe plunger area (R2 = 0.93, P < 0.001).ConclusionsVertical displacement of syringe pumps causes flow irregularities which correlate directly with syringe size and indirectly with infusion rate. Extreme vertical maneuvering of syringe pumps should be avoided. Infusion rates > or = 1 ml x hr(-1) and low-compliant, small syringes are recommended when highly concentrated drugs are administered.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.