-
- Venkatasivasai Sajja, Richard Shoge, Elizabeth McNeil, Stephen Van Albert, Donna Wilder, and Joseph Long.
- Walter Reed Army Institute of Research, Silver Spring, MD 20910, USA.
- Mil Med. 2023 Nov 8; 188 (Suppl 6): 288294288-294.
IntroductionSimulation of blast exposure in the laboratory has been inconsistent across laboratories. This is primarily because of adoption of the shock wave-generation techniques that are used in aerodynamic tests as opposed to application of blast exposures that are relevant to combat and training environments of a Warfighter. Because of the differences in blast signatures, characteristically different pathological consequences are observed among the preclinical studies. This is also further confounded by the varied exposure positioning of the animal subject (e.g., inside the blast simulator vs. at the mouth of the simulator). In this study, we compare biomechanical responses to blast exposures created in an advanced blast simulator (ABS) that generates "free-field"-like blast exposure with those produced by a traditionally applied cylindrical blast simulator (CBS) that generates a characteristically different blast signature. In addition, we have tested soft-armor vest protective responses with the ABS and CBS to compare the biomechanical responses to this form of personal protective equipment in each setting in a rodent model.Materials And MethodsAnesthetized male Sprague-Dawley rats (n = 6) were surgically probed with an intrathoracic pressure (ITP) transducer and an intracranial pressure (ICP) transducer directed into the lateral cerebral ventricle (Millar, Inc.). An ABS for short-duration blast or a CBS for long-duration blast was used to expose animals to an incident blast overpressure of 14.14 psi (impulse: 30.27 psi*msec) or 16.3 psi (impulse: 71.9 psi*msec) using a custom-made holder (n = 3-4/group). An external pitot probe located near the animal was used to measure the total pressure (tip) and static gauge (side-on) pressure. Data were recorded using a TMX-18 data acquisition system (AstroNova Inc.). MATLAB was used to analyze the recordings to identify the peak amplitudes and rise times of the pressure traces. Peak ICP, peak ITP, and their impulses were normalized by expressing them relative to the associated peak static pressure.ResultsNormalized impulse (ABS: 1.02 ± 0.03 [vest] vs. 1.02 ± 0.01 [no-vest]; CBS: 1.21 ± 0.07 [vest] vs. 1.01 ± 0.01 [no-vest]) and peak pressure for ICP (ABS: 1.03 ± 0.03 [vest] vs. 0.99 ± 0.04 [no-vest]; CBS: 1.06 ± 0.08 [vest] vs. 1.13 ± 0.06 [no-vest]) remained unaltered when comparisons are made between vest and no-vest groups, and the normalized peak ITP (ABS: 1.50 ± 0.02 [vest] vs. 1.24 ± 0.16 [no-vest]; CBS: 1.71 ± 0.20 [vest] vs. 1.37 ± 0.06 [no-vest]) showed a trend of an increase in the vest group compared to the no-vest group. However, impulses in short-duration ABS (0.94 ± 0.06 [vest] vs. 0.92 ± 0.13 [no-vest]) blast remained unaltered, whereas a significant increase of ITP impulse (1.21 ± 0.07 [vest] vs. 1.17 ± 0.01 [no-vest]) in CBS was observed.ConclusionsThe differences in the biomechanical response between ABS and CBS could be potentially attributed to the higher dynamic pressures that are imparted from long-duration CBS blasts, which could lead to chest compression and rapid acceleration/deceleration. In addition, ICP and ITP responses occur independently of each other, with no evidence of thoracic surge.Published by Oxford University Press on behalf of the Association of Military Surgeons of the United States 2023. This work is written by (a) US Government employee(s) and is in the public domain in the US.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.