- Yannik Kalbas, Yannis Hoch, Felix Karl-Ludwig Klingebiel, Octavia Klee, Davide Cester, Sascha Halvachizadeh, Till Berk, Guido A Wanner, Roman Pfeifer, Hans-Christoph Pape, and Rebecca Maria Hasler.
- Department of Trauma Surgery, University Hospital Zurich, University of Zurich, Ramistr. 100 8091 Zurich, Switzerland; Harald-Tscherne Laboratory for Orthopaedic and Trauma Research, University Hospital Zurich, University of Zurich, Ramistr. 100 8091 Zurich, Switzerland. Electronic address: yannik.kalbas@usz.ch.
- Injury. 2024 Feb 1; 55 (2): 111214111214.
Background3D-navigation for percutaneous sacroiliac (SI) screw fixation is becoming increasingly common and several studies report great advantages of this technology. However, there is still limited clinical evidence on the efficacy regarding radiation exposure for patient and personnel.MethodsThis is a retrospective, single-center cohort study. All patients who underwent percutaneous sacroiliac screw fixation for an injury of the posterior pelvic ring from 2014 to 2021 were screened. Inclusion criteria were: conclusive radiation dosage reports, signed informed consent, a twelve month follow up and a complete data set. Patients were stratified in two groups (3D-navigation (Group 3D-N) vs. control (Group F)) based on the imaging modality used. Primary outcomes were radiation exposure for patient and personnel. Secondary outcomes were reoperations, complications, and intraoperative precision.ResultsOf 392 patients screened, 174 patients (3D-N: n = 50, F: n = 124) could be included for final analysis. We noted a significant reduction of the dose corresponding to potential radiation exposure for medical personnel (-15.3 mGy, 95 %CI: -2.1 to -28.5, p = 0.0232), but also a significant increase of the dose quantifying radiation exposure for patients (+77.0 mGy, 95 %CI: +53.3 to +100.6, p < 0.0001), when using navigation. In addition, the rate of radiographic malplacement was significantly reduced (F: 11.3% vs. 3D-N: 0 %, p = 0.0113) despite a substantial increase in transsacral screw placement (F: 19.4% vs. 3D-N: 76 %).ConclusionOur data clearly suggests that the use of 3D-navigation for percutaneous SI screw fixation decreases radiation exposure for medical personnel, while increasing radiation exposure for patients. Furthermore, intraoperative precision is improved, even in more challenging operations.Copyright © 2023 The Author(s). Published by Elsevier Ltd.. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.