• Crit Care · Dec 2023

    Review Meta Analysis

    Prognostic value of capillary refill time in adult patients: a systematic review with meta-analysis.

    • Matthias Jacquet-Lagrèze, Aymeric Pernollet, Eduardo Kattan, Hafid Ait-Oufella, Delphine Chesnel, Martin Ruste, Rémi Schweizer, Bernard Allaouchiche, Glenn Hernandez, and Jean-Luc Fellahi.
    • Service d'anesthésie-Réanimation, Hôpital Cardiologique Louis Pradel, 59 Bd Pinel, 69500, Hospices Civils de LyonBron, France. matthias.jacquet-lagreze@chu-lyon.fr.
    • Crit Care. 2023 Dec 2; 27 (1): 473473.

    PurposeAcute circulatory failure leads to tissue hypoperfusion. Capillary refill time (CRT) has been widely studied, but its predictive value remains debated. We conducted a meta-analysis to assess the ability of CRT to predict death or adverse events in a context at risk or confirmed acute circulatory failure in adults.MethodMEDLINE, EMBASE, and Google scholar databases were screened for relevant studies. The pooled area under the ROC curve (AUC ROC), sensitivity, specificity, threshold, and diagnostic odds ratio using a random-effects model were determined. The primary analysis was the ability of abnormal CRT to predict death in patients with acute circulatory failure. Secondary analysis included the ability of CRT to predict death or adverse events in patients at risk or with confirmed acute circulatory failure, the comparison with lactate, and the identification of explanatory factors associated with better accuracy.ResultsA total of 60,656 patients in 23 studies were included. Concerning the primary analysis, the pooled AUC ROC of 13 studies was 0.66 (95%CI [0.59; 0.76]), and pooled sensitivity was 54% (95%CI [43; 64]). The pooled specificity was 72% (95%CI [55; 84]). The pooled diagnostic odds ratio was 3.4 (95%CI [1.4; 8.3]). Concerning the secondary analysis, the pooled AUC ROC of 23 studies was 0.69 (95%CI [0.65; 0.74]). The prognostic value of CRT compared to lactate was not significantly different. High-quality CRT was associated with a greater accuracy.ConclusionCRT poorly predicted death and adverse events in patients at risk or established acute circulatory failure. Its accuracy is greater when high-quality CRT measurement is performed.© 2023. The Author(s).

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…