• Crit Care Resusc · Dec 2020

    Circadian Hygiene in the ICU Environment (CHIE) study.

    • Rob Boots, Gabrielle Mead, Oliver Rawashdeh, Judith Bellapart, Shane Townsend, Jenny Paratz, Nicholas Garner, Pierre Clement, David Oddy, and Circadian Investigators in Critical Illness.
    • Thoracic Medicine, Royal Brisbane and Women's Hospital, Brisbane, QLD, Australia.
    • Crit Care Resusc. 2020 Dec 1; 22 (4): 361369361-369.

    AbstractObjective: To investigate the environment and care in the intensive care unit (ICU) and its relationship to patient circadian temperature disruption. Design: 30-day, prospective period prevalence study. Setting: 27-bed tertiary ICU. Participants: Patients expected to remain in the ICU for at least 24 hours. Main outcome measures: Temperature, relative humidity, light and sound intensity in the ICU; nursing interventions (using the Therapeutic Intervention Scoring System-28); and core body temperature of ICU patients. Results: Of 28 patients surveyed, 20 (71%) were mechanically ventilated. Median (interquartile range [IQR]) light intensity peaked at 07:00 at 165 (12-1218) lux with a trough at 23:00 of 15 (12-51) lux and was consistently < 100 lux between 21:00 and 06:00. Peak median (IQR) sound intensity was at 07:00 (62.55 [57.87-68.03] dB) while 58.84 (54.81-64.71) dB at 02:00. Ambient temperature and humidity varied with median (IQR) peaks of 23.11°C (22.74-23.31°C) at 16:00 and 44.07% (32.76-51.08%) at 11:00 and median troughs of 22.37°C (21.79-22.88°C) at 05:00 and 39.95% (31.53-47.95%) at 14:00, respectively. Disturbances to sleep during the night occurred due to care activities including linen changes (15 patients, 54%) and bathing (13, 46%). On the day before and the day of the study, 13 patients (47%) and 10 patients (36%), respectively, had a circadian rhythm on core body temperature without an association with illness severity, nursing intervention or environmental measures. Conclusions: The ICU has low light intensity with relative humidity and ambient temperature not aligned to normal human circadian timing. Noise levels are commonly equivalent to conversational speech while patient care procedures interrupt overnight sleep. The contribution of these factors to disrupted CBT rhythmicity is unclear.© 2020 College of Intensive Care Medicine of Australia and New Zealand.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…