• Am J Emerg Med · Mar 2024

    Randomized Controlled Trial

    A novel CPR-assist device vs. established chest compression techniques in infant CPR: A manikin study.

    • Chia-Lung Kao, Jui-Yi Tsou, Ming-Yuan Hong, Chih-Jan Chang, Yi-Fang Tu, Shao-Peng Huang, Fong-Chin Su, and Chih-Hsien Chi.
    • Department of Emergency Medicine, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
    • Am J Emerg Med. 2024 Mar 1; 77: 818681-86.

    IntroductionGuidelines for infant CPR recommend the two-thumb encircling hands technique (TTT) and the two-finger technique (TFT) for chest compression. Some devices have been designed to assist with infant CPR, but are often not readily available. Syringe plungers may serve as an alternative infant CPR assist device given their availability in most hospitals. In this study, we aimed to determine whether CPR using a syringe plunger could improve CPR quality measurements on the Resusci-Baby manikin compared with traditional methods of infant CPR.MethodsCompression area with a diameter of 1 to 2 cm is recommended in previous infant CPR device researches. In this is a randomized crossover manikin study, we examined the efficacy of the Syringe Plunger Technique (SPT) which uses the plunger of the 20 ml syringe with a 2 cm diameter flat piston, commonly available in hospital, for infant External Chest Compressions (ECC). Participants performed TTT, TFT and SPT ECC on Resusci® Baby QCPR® according to 2020 BLS guidelines.ResultsSixty healthcare providers participated in this project. The median (IQR) ECC depths in the TTT, TFT and SPT in the first minute were 41 mm (40-42), 40 mm (38-41) and 40 mm (39-41), respectively, with p < 0.001. The median (IQR) ECC recoil in the TTT, TFT and SPT groups in the first minute was 15% (1-93), 64% (18-96) and 53% (8-95), respectively, with p = 0.003. The result in the second minute had similar findings. The SPT had the best QCPR score and less fatigue.ConclusionThe performance of chest compression depth and re-rebound ratio was statistically different among the three groups. TTT has good ECC depth and depth accuracy but poor recoil. TFT is the complete opposite. SPT can achieve a depth close to TTT and has a good recoil performance as TFT. Regarding comprehensive performance, SPT obtains the highest QCPR score, and SPT is also less fatigued. SPT may be an effective alternative technique for infant CPR.Copyright © 2023. Published by Elsevier Inc.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.