• Medicina · Dec 2023

    Comparison of Preoperative ECG Screening and Device-Based Vector Analysis in Patients Receiving a Subcutaneous Implantable Cardioverter-Defibrillator.

    • Szymon Budrejko, Agnieszka Zienciuk-Krajka, Ludmiła Daniłowicz-Szymanowicz, and Maciej Kempa.
    • Department of Cardiology and Electrotherapy, Faculty of Medicine, Medical University of Gdansk, Smoluchowskiego 17, 80-214 Gdansk, Poland.
    • Medicina (Kaunas). 2023 Dec 16; 59 (12).

    AbstractBackground and Objectives: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) provide protection against sudden cardiac death from outside the cardiovascular system. ECG screening is a prerequisite for implantation, but the reproducibility of its results post-operatively in the device is only partial. We aimed to compare the results of ECG screening with device-based sensing vector analysis. Materials and Methods: We screened the hospital records of all S-ICD recipients in our clinic. All of them had pre-operative ECG screening performed (primary, secondary, and alternate vectors). The results were compared with device-based vector analysis to determine the relation of the pre- and post-operative vector availability. Results: Complete ECG screening and device-based vector analysis were obtained for 103 patients. At least two acceptable vectors were found in 97.1% of the patients pre-operatively and in 96.1% post-operatively. When comparing vectors in terms of agreement (OK or FAIL) pre- and post-operatively, in 89.3% of the patients, the result for the primary vector was the same in both situations; for the secondary, it was in 84.5%, and for the alternate, it was in 74.8% of patients, respectively. In 55.3% of patients, all three vectors were labeled the same (OK or FAIL); in 37.9%, two vectors had the same result, and in 6.8%, only one vector had the same result pre- and post-operatively. The number of available vectors was the same pre- and post-operatively in 62.1% of patients, while in 15.5%, it was lower, and in 22.3% of patients, it was higher than observed during screening. Conclusions: Routine clinical pre-operative screening allowed for a good selection of candidates for S-ICD implantation. All patients had at least one vector available post-operatively. The final number of vectors available in the device-based analysis in most patients was at least the same (or higher) than during screening. The repeatability of the positive result for a single vector was high.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.