• Reg Anesth Pain Med · Mar 2007

    Spread of injectate associated with radial or median nerve-type motor response during infraclavicular brachial-plexus block: an ultrasound evaluation.

    • Sébastien Bloc, Thierry Garnier, Bernard Komly, Hugues Asfazadourian, Pascal Leclerc, Luc Mercadal, Bertrand Morel, and Gilles Dhonneur.
    • Department of Anesthesiology, Private Hospital, Claude Galien, Quincy-sous-Snart, Paris, France.
    • Reg Anesth Pain Med. 2007 Mar 1;32(2):130-5.

    Background And ObjectivesWe have compared ultrasound characteristics of spread during infraclavicular brachial-plexus blocks by use of electrically evoked radial-nerve- or median-nerve-type distal motor responses to guide the injection of 30 mL of 1.5% mepivacaine.MethodsConsecutive patients who required surgery distal to the upper arm were prospectively included in this study. With radial- or median-evoked distal motor response at a stimulating current intensity of less than 0.5 mA, patients were distributed into 2 equal groups. An independent investigator blinded to the evoked response described ultrasound characteristics of the spread of local anesthetic and assessed block quality 30 minutes after placement. A quality diffusion score proportional to the extent and intensity of spread around the axillary artery was used, and dynamic movements during injection were noted.ResultsThirty-two patients were included. With radial-nerve-type motor response, the success rate of infraclavicular plexus block was 100%, but 3 supplemental axillary blocks were requested with median-nerve-type motor response. Quality diffusion scores were significantly higher with radial-nerve-type as compared with median-nerve-type motor response (P = .03). Injection after radial-nerve-type motor response resulted in a typical and reproducible ultrasound feature of posterior local-anesthetic spread associated with medial and upper movement of the axillary artery. With median-nerve-type motor response, failed blocks were associated with a specific posterior displacement of the axillary artery that resulted from superficial spread.ConclusionWe have demonstrated that as compared with median-nerve-type motor response, injection performed after a radial-nerve-type motor response promoted reproducible and remarkable ultrasound spread characteristics associated with complete sensory block of the 3 cords at 30 minutes.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…