-
Reg Anesth Pain Med · Mar 2007
Spread of injectate associated with radial or median nerve-type motor response during infraclavicular brachial-plexus block: an ultrasound evaluation.
- Sébastien Bloc, Thierry Garnier, Bernard Komly, Hugues Asfazadourian, Pascal Leclerc, Luc Mercadal, Bertrand Morel, and Gilles Dhonneur.
- Department of Anesthesiology, Private Hospital, Claude Galien, Quincy-sous-Snart, Paris, France.
- Reg Anesth Pain Med. 2007 Mar 1;32(2):130-5.
Background And ObjectivesWe have compared ultrasound characteristics of spread during infraclavicular brachial-plexus blocks by use of electrically evoked radial-nerve- or median-nerve-type distal motor responses to guide the injection of 30 mL of 1.5% mepivacaine.MethodsConsecutive patients who required surgery distal to the upper arm were prospectively included in this study. With radial- or median-evoked distal motor response at a stimulating current intensity of less than 0.5 mA, patients were distributed into 2 equal groups. An independent investigator blinded to the evoked response described ultrasound characteristics of the spread of local anesthetic and assessed block quality 30 minutes after placement. A quality diffusion score proportional to the extent and intensity of spread around the axillary artery was used, and dynamic movements during injection were noted.ResultsThirty-two patients were included. With radial-nerve-type motor response, the success rate of infraclavicular plexus block was 100%, but 3 supplemental axillary blocks were requested with median-nerve-type motor response. Quality diffusion scores were significantly higher with radial-nerve-type as compared with median-nerve-type motor response (P = .03). Injection after radial-nerve-type motor response resulted in a typical and reproducible ultrasound feature of posterior local-anesthetic spread associated with medial and upper movement of the axillary artery. With median-nerve-type motor response, failed blocks were associated with a specific posterior displacement of the axillary artery that resulted from superficial spread.ConclusionWe have demonstrated that as compared with median-nerve-type motor response, injection performed after a radial-nerve-type motor response promoted reproducible and remarkable ultrasound spread characteristics associated with complete sensory block of the 3 cords at 30 minutes.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.