J Paediatr Child Health · Oct 2001
Inspired gas humidity during mechanical ventilation: effects of humidification chamber, airway temperature probe position and environmental conditions.
- D A Todd, J Boyd, J Lloyd, and E John.
- Department of Neonatology, Westmead Hospital, Sydney, NSW, Australia. David@thetodds.enterprise-plc.com
- J Paediatr Child Health. 2001 Oct 1;37(5):489-94.
ObjectivesTo determine the inspired gas humidity during mechanical ventilation with: (i) four different humidification chambers; (ii) two airway temperature probe (ATP) positions; (iii) five different humidicrib temperatures; and (iv) insulating the inspiratory limb with bubble wrap.MethodologyAn observational study in the Neonatal Laboratory and Neonatal Intensive Care Unit, Westmead Hospital. The humidity of the inspired gas was measured at the proximal end of the endotracheal tube (ETT) during mechanical ventilation. Inspired humidity measurements were made with four different humidification chambers (Fisher & Paykel (F&P Healthcare Pty Ltd, Auckland, New Zealand) auto refill MR290. F&P manual refill MR310, Suruga (Suruga Inc. Humidifiers, Vincent Medical, Dongguan, China) manual refill MI-20 and MI-10F) with the humidity control (relative humidity setting) set at - 2. Measurements were made with the ATP positioned either; (A) at the distal end of the inspiratory tube inside the humidicrib or (B) outside the humidicrib 50 cm proximal to the ETT. The inspired gas temperatures were set at 36.5 degrees C and at 39.0 degrees C, respectively. For each of the different humidification chambers and ATP positions, inspired humidity measurements were made with the humidicrib temperature set at 30.8, 32.9, 35.2, 36.2, or 37.2 degrees C. Two further sets of measurements were made, one with the inspiratory limb insulated with bubble wrap and the second set without bubble wrap.ResultsThere were significant differences in inspired humidity with the four humidification chambers at both ATP positions at all humidicrib temperatures. Both Suruga humidification chambers produced significantly higher inspired gas humidities under most conditions. Positioning the ATP outside the humidicrib produced significantly higher inspired gas humidities than with the ATP inside the humidicrib. Insulating the inspiratory tubing with bubble wrap also significantly improved the inspired gas humidity.ConclusionsSignificant differences in inspired gas humidity were found with the humidification chambers tested. The position of the ATP and the set temperature had a significant impact on the absolute humidity of the inspired gas. In general, higher inspired gas humidities were obtained with the ATP outside the humidicrib. However, condensation of water close to the ETT appeared at low humidicrib temperatures (< 36.2 degrees C) with the ATP outside the humidicrib and extreme care should be taken that particulate water does not enter the lungs under these conditions.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.