• Jpen Parenter Enter · Nov 1992

    Case Reports

    Placement of a duodenal feeding tube via gastrostoma with fiberoptic bronchoscope.

    • T S Lee and Y Wu.
    • Department of Anesthesiology, Harbor-UCLA Medical Center, Torrance 90509.
    • Jpen Parenter Enter. 1992 Nov 1;16(6):579-80.

    AbstractWe report a case of esophageal disruption that required a duodenal feeding tube. Because of collapse of the gastric outlet secondary to severe emaciation, several attempts to place a tube into the duodenum via gastrostoma had ended in failure. We finally were able to accomplish it with the aid of a fiberoptic bronchoscope and a Swan-Ganz catheter. The procedure is described and discussed.